4. For best protection, mount all sensors below a 45
°
cone from the lightning spike, as shown in the drawing
below. Sensors on top-mount or Z booms may be at the top of the tower. For sensors on side mount booms,
keep the boom at least 0.6 m (2 feet) below the top of the tower.
5. Attach the bottom end of the ground wire to BOTH ground rods using the supplied clamps. This is easiest if
the first clamp is threaded over the end of the ground wire before leading the wire to the second clamp.