boom and the tower. In the rare case of using a vane mounting angle other than 0 or 180, the angle is measured
clockwise starting from the 0 degree alignment example.
An explanation of the Boom Bearing and Vane Mounting Angle is available by hovering over the Vane Mounting
Angle tooltip in SymphoniePRO Desktop Application.
For wind vanes with dead bands, the number of degrees of dead band to the east and west of north should be
indicated in the Dead Band Compensation fields.
Scale Factor and Offset values are entered in SI units.
3.2.4 Signal Type or Excitation
Signal Type and Excitation settings are automatically populated when selecting a sensor from the drop-down
list. Do not change these settings unless you are certain that you are using a sensor that requires a different
setting from the default.
Signal Type choices for counter channels include Coil and Pulsed. When Pulsed is selected, the user can
additonally choose to enable a 12K ohm internal pull-up resistor to generate a 3.3 V pulse from the sensor
output signal. The pull-up is typically utilized for sensors that use switch closures to create the signal. Notice that
when a sensor is selected from the “Load From Defaults” list, the Signal Type is automatically appropriately
configured.
Summary of Contents for SymphoniePRO
Page 1: ......
Page 74: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 74 11 January 2018 ...
Page 76: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 76 11 January 2018 ...
Page 77: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 77 11 January 2018 ...
Page 78: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 78 11 January 2018 ...
Page 134: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 134 11 January 2018 ...
Page 137: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 137 11 January 2018 ...
Page 139: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 139 11 January 2018 ...
Page 142: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 142 11 January 2018 ...