3.6.1 Connecting the Wiring Panel to the Logger
Connect the wiring panel to the SymphoniePRO logger using the 62 pin cable connector. Use the thumbscrews
to secure the connection at both ends. Once the wiring panel is connected, you may use the sensor wiring
diagram in section
to connect a few test sensors.
3.6.2 Testing Remote Communications
We recommend performing a communications test when using the iPack to ensure that your connections are
working as expected before heading to the field. Be sure you are in a location with coverage and that the
antenna is connected. Also make sure that the frequency for the connection mode you wish to use (MetLink or
Email) is not set to Disabled on the Schedules screen.
Performing a “Connection Test” through the Functions menu ([Home][2][2][1]) allows you to test different
aspects of the communications. After the test is completed, verify that the raw data file was received by the
intended recipient(s).
A good first test is MetLink Diagnosis [Home][2][2][1][4]. This test verifies that the system can connect to a
fixed IP address at NRG Systems. The logger’s display will show a series of status messages followed by the
transfer and receipt of bytes of information. The number of clients will go from 0 to 1. The system will then
disconnect, and the number of clients will go back to 0.
If the system is set up to send data via email, use Email No File [Home][2][2][1][5] or Email One File
[Home][2][2][1][6] to verify that the modem and email functions are working well. Initiate Primary
[Home][2][2][1][1] verifies that the logger can connect to the assigned IP address behind your company’s
firewall and communicate with SymphoniePRO Desktop Application. MetLink Listen [Home][2][2][1][3] puts the
logger in listening mode so that a test connection can be attempted with the SymphoniePRO Desktop
Application. When a successful MetLink connection is made, you will see the client count increase.
SymphoniePRO Desktop Application is designed with many features for testing the various types of connections
SymphoniePRO can utilize. The Listen Now, Email Now,Test Email Settings, and Test buttons on the Schedules
screen can be used to verify and troubeshoot any connection issues. The Display iPack Status button can be
found on both the Schedules screen and the iPack screen, and a log of the current iPack’s connection can be
obtained by clicking View log file at the bottom of the iPack Status screen.
3.6.3 Reading a Raw File
Read the raw file sent during the test call to confirm that sensor configurations are correct. You can do this by
choosing Import Raw Logger Data files (*.RLD) from the File menu and then use Data Export in the Site Utilities
screen to export the data in *.txt format for viewing in Excel, Notepad, etc.
Data File Format
File name format is as follows: SSSSSS_YYYY-MM-DD_HH.MM_FFFFFF.rld
SSSSSS = 6 digit site number
Summary of Contents for SymphoniePRO
Page 1: ......
Page 74: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 74 11 January 2018 ...
Page 76: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 76 11 January 2018 ...
Page 77: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 77 11 January 2018 ...
Page 78: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 78 11 January 2018 ...
Page 134: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 134 11 January 2018 ...
Page 137: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 137 11 January 2018 ...
Page 139: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 139 11 January 2018 ...
Page 142: ...SymphoniePRO User Manual Rev 8 support nrgsystems com Page 142 11 January 2018 ...