G-13.mft MDB/S1
G
LOSSARY
63
National Rejectors, Inc. GmbH, Buxtehude
Glossary
Acceptance band
A range of acceptable measured values of one
→
coin type
(with specific
→
coin properties)
defined by an upper and
lower limit value.
Acceptance gate
The acceptance gate diverts the inserted coins into the
acceptance or return area of the coin validator.
Accepted coin sensors
The accepted coin sensors are positioned in front of the
cash-box coin outlet of the coin validator and check whether
accepted coins fall unhindered into the cash-box chute.
Attraction duration
The attraction duration is used to specify the period of time for
which the solenoid is to attract the
→
acceptance gate
in
order to guide the accepted coins to the cash-box or an
external sorting device.
Block
→
Memory block
Channel
→
Coin channel
Coin acceptance band
→
Acceptance band
Coin channel
Coin channels are used to describe
→
coin types
using their
different
→
coin properties
(alloy, size, etc.). The required
coin properties of a coin type are defined in
→
acceptance
bands
which are assigned to the coin channels together with
other coin information for further processing along.
Coin properties
Coin properties are measured when a coin is inserted into the
coin validator. These are e.g. material, thickness, volume,
minting, diameter, mass, hardness, etc.
Coin type
One coin type includes all coins for which the
→
coin
properties
agree.
Coin value
The value of a
→
coin type
that is transmitted from the coin
validator to the machine.
Data block update
When updating a data block (set) (2 data blocks) using
WinEMP or PalmEMP2, the data blocks for the connected
coin validators are loaded quickly and easily from the internal
hard disk of your PC into the coin validator. By doing this, a
new data block is loaded into
→
memory block
0 (and
memory block 1). The new data blocks contain different
configurations of
→
coin channel
data, e.g. current limit
values of the
→
acceptance bands
for a currency or new coin
or sorting information.
Summary of Contents for G-13.mft MDB/S1
Page 2: ......
Page 6: ......
Page 43: ...G 13 mftMDB S1 TECHNICALDATA 43 National Rejectors Inc GmbH Buxtehude ...
Page 49: ...G 13 mftMDB S1 TECHNICALDATA 49 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 52: ...TECHNICALDATA G 13 mftMDB S1 52 National Rejectors Inc GmbH Buxtehude View from the side ...
Page 54: ...TECHNICALDATA G 13 mftMDB S1 54 National Rejectors Inc GmbH Buxtehude View from right ...
Page 56: ...TECHNICALDATA G 13 mftMDB S1 56 National Rejectors Inc GmbH Buxtehude View from right ...