R
EMEDYING
FAULTS
G-46 MDB
42
National Rejectors, Inc. GmbH, Buxtehude
Display
InFo-01
InFo-09
InFo-13
InFo-80
Meaning
return function active
string sensor active, as string was
recognized by the string sensor
check sum error in programming functions
which, despite being incorrectly adjusted,
only restricts G-46 function
machine blocks G-46
Remedy
check return lever
check sensor
check corresponding functions by means
of setting module or PC software
"WinEMP"
check machine
The following status messages can indicate problems with the
machine. Nevertheless, the changer operates without fault
.