When deflating a chamber, simply push the valve stem in and turn it counterclockwise to lock 
it open. It’s best to close the valves when transporting the deflated boat uncovered in wet 
conditions in order to keep moisture out of the chambers.

FRAME

Your Drifter’s frame is as innovative as the hull. In the center section, our patented LoPro™ 
system lets you move and adjust the foot bar and oar mounts. 

We’ve included an assembly DVD and printed instructions. First, watch the DVD to familiarize 
yourself with the work flow. Then, grab a buddy and put your Drifter together. Be sure to read 
and closely follow the printed instructions; they contain detailed descriptions and assembly tips 
not covered in the DVD.

If you’re rolling your Drifter up for transport or storage, it’s easy to take the frame out in three 
sections. First, remove the dry box, then loosen the four U-bolts from the side rail ends, and lift 
out the center section. You can remove the front and rear casting platform section by opening 
the ClampIT Frame Attachments securing them.  

VALVES

Leafield C7 Valves

To open the valve, first unscrew the valve cap, then press down on the spring-loaded valve 
stem and turn it counterclockwise. The valve stem will now be locked in the open position, 
allowing air to move freely in and out through the valve. To close the valve, push down on the 
valve stem and turn clockwise. The stem will pop back up, sealing the valve shut. In the closed 
position, you can still pump air into the chamber, but when you remove the pump, the valve 
will not allow air to escape. When you’re finished, screw the plastic valve cap back on to keep 
water and dirt out of the inner valve.

Cleaning the Leafield C7 Valve

If the inner parts of your valve become dirty, the rubber seal may not seal fully against the valve 
body, thus allowing air to escape. You can clean the inner valve parts to restore the airtight seal. 
Your repair kit contains a flat aluminum valve wrench that you can use to remove the valve from 
the boat. Threads are: clockwise to tighten, counterclockwise to loosen. It’s easier to loosen the 
valve with the chamber inflated. The outer half of the valve unscrews from the inner half. When 
you remove the outer half of the valve, take care not to lose the inner half inside the chamber. 
With the outer half in your hand, push down and turn the valve stem counterclockwise. This lifts 
the rubber seal off the valve base. Use a cotton swab, or 
something similar, to remove any dirt and grime that has built up on the rubber seal. 
Hand-tighten the outer valve piece back into the valve base. Inflate the chamber fully, and 
then use the valve wrench to completely tighten the valve. Make sure none of the drop-stitch 
threads interfere with sealing the inner and outer valve pieces.

MAINTENANCE AND CLEANING

Proper care and maintenance will improve your Drifter’s appearance and longevity. Clean 
and inspect the boat after each use. We recommend you coat your boat with 303 Aerospace 
Protectant (available through NRS or your local dealer) every few months during the season, 
and before long-term storage, to protect against UV damage and degradation. 

Take care to keep moisture from getting inside the air chambers. Water can enter the 
chambers during in-the-field repairs or if the valves are left open during wet weather. If you find 
that moisture and mildew have accumulated in your boat’s air chambers, the chambers must 
be aired out. Remove the valve of the affected chamber and pour out any liquid water. Run the 
hose of an electric air pump or vacuum cleaner exhaust through the valve hole. Turn the unit on 
and allow the air to circulate into the chamber and out through the valve hole for several hours 
until all the moisture is gone.

Summary of Contents for Freestone Drifter

Page 1: ...800 635 5202 nrs com 1 Freestone Drifter OWNER S MANUAL ...

Page 2: ...ield C7 valve needs to be in the closed position Push the valve stem in and turn it clockwise so that the stem pops up sealing the valve Inflate the floor first to full pressure Frame assembly is easier when you inflate the side walls until they are fully formed but still soft After the frame is installed bring the side walls up to 8 9 psi air pressure As the outside air temperature and altitude c...

Page 3: ...ber seal may not seal fully against the valve body thus allowing air to escape You can clean the inner valve parts to restore the airtight seal Your repair kit contains a flat aluminum valve wrench that you can use to remove the valve from the boat Threads are clockwise to tighten counterclockwise to loosen It s easier to loosen the valve with the chamber inflated The outer half of the valve unscr...

Page 4: ... both surfaces together in a rolling motion Apply pressure to the entire glued surface using the roller Vigorously roll over the patch in multiple directions working from the inside to the outside of the patch This step is very important because it forces air bubbles out and helps the two surfaces bond Use a lint free towel and MEK to wipe up excess glue Allow the repair to cure for as long as pos...

Page 5: ...o stored boats so take precautions to prevent this If you keep your Drifter on a trailer cover it when not in use to protect it from sun damage Also reduce inflation pressure to prevent accidental overinflation CAUTION Safety Warning Paddlesports can be dangerous and physically demanding Participating in paddlesports may cause serious injury or death Follow these safety standards when using this p...

Page 6: ...ly set forth herein NRS disclaims all warranties express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose EXCLUSIONS FROM LIMITED WARRANTY Deterioration of a boat increases dramatically when water is allowed to stand in the chambers Since this condition can be remedied only by the owner s care any problems attributed to water le...