background image

LI-973(A)

PROGRAMMING INSTRUCTIONS

SA130

BATTERY INSTALLATION

The timer is shipped with 2 CR2032 batteries. Please follow below procedures for battery 

installation.

1. Remove the timer from the wall socket.

2. Using a small flat screwdriver, pry the battery holder open. The 

SA130

 uses two 

CR2032 batteries.

3. Install two CR2032 batteries into the battery holder, making sure that the 

+

 and 

 

polarities match up with the diagram printed on the unit.

4. When the batteries are in place, press the battery holder back into its original position.

5. If the timer is not running after batteries are installed, you may need to reset the timer. 

Using the point of a pencil, press the

 RESET 

button located on the front panel.

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

FRONT 

TIMED 

UNTIMED

5 On/Off Button

Open 

Battery 

Door

BATTERY INSTALLATION

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

AVANT

TEMPORISÉ

NON TEMPORISÉ

5 On/Off Button

Compartiment 

des piles 

ouvert

REMPLACEMENT DES PILES

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

FRENTE

TEMPORIZADO

NO TEMPORIZADA

5 On/Off Button

Abra la 

puerta de 

la batería

CAMBIO DE BATERÍAS

CONTACT RATINGS:

• 120VAC, 60Hz

• 15A Resistive and Inductive

• 5 A, 500 W Tungsten

• 1/2 HP Motor

Risk of electric shock

•    No Serviceable parts inside- Do not open or tamper with unit.

•    Plug directly into an electric outlet

•    For indoor use only

•    Remove timer from outlet  before cleaning

•    Keep children away from timer & outlet

Risk of fire

•   For only 120 volt usage

•   Do not use to control irons and cooking appliances, etc.

•   Do not exceed the recommended electrical ratings

CAUTION:

LAMP INSTALLATION

The 

SA130

 has two receptacle outlets - one is an untimed extra outlet which always has 

power; the other is a timed outlet which is controlled by the 

SA130

 timer. Make sure to 

connect your lamp to the proper outlet. Please note that the total rating (untimed and 

timed outlet) of lamps/appliances connected to the timer must not exceed the 

SA130

 

rating.

SET THE CLOCK

1. Press and hold the 

TIME

 button until the display is flashing.

2. Press and hold the 

FWD

 button to rapidly advance the time forward, or the 

REV

 button 

to rapidly change the time backward. Release button when the correct time is displayed. 

PM Indicator is on the lower right corner of the display (there is no AM indicator). 

Note:

 While pressing either 

FWD

 or 

REV

 button the minutes will begin at a moderate 

pace, then get faster. This will assist you in setting the time quickly and accurately.

3. Press the 

TIME

 button again or wait for 10 seconds to exit time setting mode.

4. Slide the 

DST 

Switch, to “+1” to increase the current time 1 hour for daylight saving 

time. The 

DST

 Indicator is on the upper right corner of the display.

SET THE PROGRAMMED TIME

SA130 HAS 2 INDEPENDENT PROGRAMMABLE SCHEDULES.

1. Press 

MODE

 button until “PROGRAM 1” is displayed on the upper left corner of the 

display.

2. Press and hold the 

PROGRAM

 button until the display flashes.

3. The display will change to show ON time for Program 1 and flash. The “ON” icon will 

appear. Use 

FWD

 button and 

REV 

button to adjust ON time.

4. Press the 

PROGRAM

 button again or wait for 10 seconds, it will change to display OFF 

time. The “OFF” icon will appear. Use 

FWD

 button and 

REV

 button to adjust the OFF time.

5. Press the 

PROGRAM

 button once more or wait for 10 seconds to return to normal 

mode. Display will change back to show real time.

6. To program 2nd schedule, just follow step 1-5 but press 

MODE

 Button until “PROGRAM 

2” is displayed.

TIMER OPERATION

ACTIVATING THE TIMER

After programming the timer, you need to activate a schedule. Press 

MODE

 button until 

“PROGRAM 1”, “PROGRAM 2” or “PROGRAM 12” is displayed. Timer is in Automatic mode 

and will follow schedule selected (1, 2 or both.) 

NOTE:

 Make sure to test that the power switch on your lamp/appliance is in the ON 

position before you plug it into the timed outlet.

DEACTIVATING THE TIMER

Press 

MODE

 button until OFF is showing. Timer is in Manual mode and schedules are 

disabled.

MANUAL OVERRIDE

To override the ON or OFF settings, press 

ON/OFF

 button. To activate 

ON/OFF 

button, 

you can push on the hinged front cover. The override setting will change at the next timed 

event.

This product has passed

ETL testing. It is certified

and complies with both

U.S. and Canadian product 

safety standards.

ONE YEAR LIMITED WARRANTY: If this product 

fails because of a manufacturing defect within 

one year after purchase, we will, at our option, 

either repair or replace it at no charge. Our 

warranty does not cover damage caused by 

accident, abuse or misuse. We assume no 

further liability with respect to the sale or use 

of this product. THIS WARRANTY IS IN LIEU 

OF ALL OTHER WARRANTIES, EXPRESSED OR 

IMPLIED, INCLUDING THE WARRANTY OF 

MERCHANTABILITY. We make no warranty with 

respect to the fitness of any goods for the users 

particular application. This warranty gives you 

specific legal rights, and you also may have other 

rights which vary from state to state.

It is our intent to provide accurate and current 

specification information. However, in the interest 

of product improvement, TORK may alter the 

specifications or constructional details without 

prior notice.

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

FRONT 

TIMED 

UNTIMED

5 On/Off Button

Open 

Battery 

Door

BATTERY INSTALLATION

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

AVANT

TEMPORISÉ

NON TEMPORISÉ

5 On/Off Button

Compartiment 

des piles 

ouvert

REMPLACEMENT DES PILES

RESET Button 3

DST Switch        2

PROGRAM Button 4

6 TIME Button

7 FWD Button
8 REV Button

MODE Button         1

FRENTE

TEMPORIZADO

NO TEMPORIZADA

5 On/Off Button

Abra la 

puerta de 

la batería

CAMBIO DE BATERÍAS

FOR TECHNICAL SUPPORT: SOUTIEN TECHNIQUE : PARA COMUNICARSE CON EL SERVICIO TÉCNICO: techsupport@nsiindustries.com 877.230.7874

Reviews: