© Brüel & Kjær Vibro
● C104958.002 / V04 ●
Page 15 of 32
Technical alterations reserved!
Brüel & Kjær Vibro
│
Instructions Sensor ds821 4 mm
Installation
EN
UNRESTRICTED DOCUMENT
4.2.2
Screw mounting
NOTE!
The screws for the installation are not included in the delivery contents.
A suitable surface of at least 7x10 cm is required for screw mounting:
•
Solid metal: .............. Solid metal: M4x12 A2-70
.................................. 2 washers A2, ................ ................... inner diameter 4.5 mm
.................................. ................... .................... ................... Depth of thread: 12 mm
•
Steel: ........................ 2 sheet metal screws A2
.................................. 2 washers A2, ................ ................... inner diameter 4.5 mm
..................................
Steel thickness 1.2…1.4 mm ............. Core hole diameter: 3.3 mm
•
Aluminium ................ 2 sheet metal screws A2
.................................. 2 washers A2, ................ ................... inner diameter 4.5 mm
..................................
Aluminium thickness 1.2…1.4 mm ..... Core hole diameter: 3.4 mm
1.
Mark the positions for both drill holes (section 8.2 Dimensioning of assembly adapter).
2.
Drill two mounting holes.
3.
Connect the assembly adapter with the driver.
4.
Mount the assembly adapter in the mounting surface with two screws and the washers using
the mounting tabs and secure (e.g. Loctite 243 medium strength, Loctite 270 high strength):
5.
Tighten screws alternately.