— 9-12 —
9.1.8.1. Velocity Monitor
l
The user can monitor the velocity of the Motor by measuring the voltage between VELOCITY
and GND check pins on the front panel.
u
When the resolver is set to 12-bit resolution
Note: ±10 V is only a typical value; actual values vary slightly. The voltage is not a precise
representation of the velocity.
Figure 9-9
Minus direction
maximum velocity
Plus direction
maximum velocity
+10V
-10V
u
When the resolver is set to 10-bit resolution or automatic resolution switching
Note: ±7.5 V is only a typical value; actual values vary slightly. The voltage is not a precise
representation of the velocity.
Figure 9-10
Minus direction
maximum velocity
Plus direction
maximum velocity
+10V
-10V
Table 9-4 : Maximum velocity
Resolver resolution
12-bit setting
Automatic resolution switching or 10-bit setting
Maximum velocity
600 mm/s
1800 mm/s
l
Automatic resolution switching, 12-bit setting and 10-bit setting are selected by the RR
parameter.