— 9-32 —
9.3.3.2. Initial Setting
l
The password is necessary for inputting initial setting parameters.
l
The initial setting values become valid when the power is turned on next time.
l
Perform initial setting before making multi-axis connection.
Table 9-9 : Initial setting
Item
RS-232C
parameter
Data
range
Shipping
set
Function
Daisy-chain
communication,
axis number setting
AN data
0~15
0
The set data becomes the axis number of
multi-axis communication.
Daisy-chain
communication
mode selection
CM data
0, 1
0
CM0: standard (single driver) communication,
CM1: daisy-chain communication
9.3.3.3. Interfacing
(1) Connecting data communication lines
l
Connect data communication lines sequentially : First connect the output of the terminal with the
input of axis 0, then connect the output of axis 0 with the input of axis 1 and so forth. (See
Figure 9-34.)
l
Connect the output of the final axis with the input of the terminal.
Figure 9-34: Data line connection
RXD TXD
Driver Unit
#0
Terminal
TXD RXD
RXD TXD
Driver Unit
#1
RXD TXD
Driver Unit
#2
~
RXD TXD
Driver Unit
#15
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com