— 10-16 —
10.6. Jog Operation
l
Jog operation is available when the Driver Unit is set to Type 7.
l
Set system to servo-on. (SVON input ON)
l
Turning on the Jog input makes the Motor start acceleration and moving. The Motor keeps
moving while the Jog input remains on. When the Jog input is off, the Motor starts decelerating,
then stops.
l
When the DIR input is off, the Motor moves to PLS direction. When the DIR input is on, it
moves to MNS direction.
l
Jog operation parameter
JA: Jog acceleration
JV: Jog velocity
Figure 10-12: Jog operation timing
Jog input
DIR input
IPOS output
(FW=0)
IPOS output
(FW
¹
0)
Motor
movement
Close
Open
Close
Open
ON
OFF
ON
OFF
JA
PLS direction
velocity
MNS direction
velocity
JV
JA
JA
JV
Note: When the DIR input is switched during Motor moves as shown in the above chart, the
Motor decelerates, then reverses the direction of motion.