— 12-9 —
«
«
«
«
FC
: Friction Compensation
Format
: FC data
Data
: 0 ~ 2047
Shipping set
: 0
Default
: 0
l
“FC” is used to specify a compensation value to cancel rotational static friction of the Motor.
l
If 0 is specified in ‘data’ the function is deactivated.
l
Parameter FC can be obtained with the formula shown below.
l
The setting can be read with “TS” or “?FC” command.
«
«
«
«
FD
: Feed Back Direction Mode
Format
: FD data
Data
: 0, 1
Shipping set
: 0
Default
: 0
l
Reverses the output timing between øA and øB of the position feedback signal.
FD0: Standard ; øA signal is ahead of øB signal when Motor moves toward PLS direction.
FD1: Reverse ; øB signal is ahead of øA signal when Motor moves toward MNS direction.
l
“TS” or “?FD” command reports the current setting.
«
«
«
«
FF
: Feed Forward Gain
Format
: FF data
Data
: 0.0000 ~ 1.0000
Shipping set
: 0
Default
: 0
l
FF sets the feed forward compensation gain.
l
For more details, refer to “9.2.3. Feed Forward Compensation.”
l
Setting 0 cancels the feed forward compensation function.
l
“TS” or “?FF” command reports the current setting.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com