— 12-17 —
LG
: Lower Gain
Format
: LG data
Data range
: 0 ~ 100 [%]
Shipping set
: 50
Default
: Not omissible
!
Caution : Factory use only. Do not change the setting.
«
«
«
«
LO
: Load Inertia
Format
: LO data
Data range
: 0.0 ~ 500.0 [kg]
Shipping set
: 0
Default
: 0
l
LO sets actual load inertia automatically when AT command (automatic tuning) is executed.
l
“TS” or “?LO” command reads out the current setting.
l
Data of PG, VG, VI, and MA parameters will be automatically reset when LO is changed.
l
Change of PG and VI data will clear LO data.
«
«
«
«
LR
: Low Torque Ripple
Format
: LR data
Data range
: 0, 1
Shipping set
: 0
Default
: 0
l
Sets force specification.
0: Standard
1: Low force ripple. (the maximum Motor force will be lowered)
l
“TS” or “?LR” command reports the current setting.
MA : Move Acceleration
Format
: MA data
Data
: 0.01 ~ 2.50 [G]
Shipping set
: 0.05
Default
: Not omissible
l
Sets the rotational acceleration of the RS-232C communication positioning.
l
“TS” or “?MA” command reports the current setting.
l
“MA/AJ” command gets into adjusting mode.