background image

4

 

12 Gallon Extractor 

 

 

Dear Customer: 
Congratulations on the purchase of your new 12 Gallon Extractor. 

 

Like any other piece of machinery or technology, extractors require the 
proper maintenance and care to keep the product working over extended 
use. Neglecting your machine, abusing it or not operating it properly can 
void its warranty and prevent the machine from performing to the quality 
and standard you’d expect. 

 

If you have any warranty concerns or questions, please review this manual 
thoroughly or do not hesitate to contact your distributor. If there are 
questions regarding maintenance, replacement or ordering parts please 
contact an authorized Service Center. 

 

Before using your extractor, please read this manually thoroughly. 

 

120 Volt Grounding Instructions 
This machine must be grounded. If it should malfunction or break-down, 
grounding provides a path of least resistance for electrical shock. This 
machine is equipped with a cord having an equipment grounding conductor 
and grounding plug. The plug must be plugged into an appropriate outlet 
that is properly installed in accordance with all local codes and ordinances. 
Do not remove ground pin; if missing, replace plug before use. 

 

Improper installation of the equipment-grounding conductor can result 
in a risk of electric shock. Be sure to check with a qualified electrician 
or service person if you are in doubt as to whether the outlet is properly 
grounded. If the plug will not fit in the outlet do not modify either the 
plug or the machine’s cord, instead have a proper outlet installed by 
a qualified technician. 

 

This machine is for use on a nominal 120 volt circuit and with a grounding 
plug similar to the one in Figure 1 below. If a proper outlet is not available, 
follow the illustrations of Figure 2 & 3 to install a temporary-grounding 
plug. This temporary work-around should be used only until a proper 
outlet (Figure 1) can be installed by a qualified electrician. When and if 
this type of adapter is employed, screw the adapter’s extended tab into 
place with a metal screw. However, grounding adapters are not approved 
for use in Canada. Again, be sure to check the grounding pin for damages 
and replace if necessary. The Green, or Green-Yellow, wire in the cord is 
the grounding wire. When replacing a plug, this wire must be attached to 
only the grounding pin. 

 
220-240 Volt Grounding Instructions 

This machine must be grounded. If it should malfunction or break-down, 
grounding provides a path of least resistance for electrical shock. This  machine is 
equipped with a cord having an equipment grounding conductor  and grounding 
plug. The plug must be plugged into an appropriate outlet that is properly installed 
in accordance with all local codes and ordinances.  Do not remove ground pin; if 
missing, replace plug before use. 

 

Improper installation of the equipment-grounding conductor can result 
in a risk of electric shock. Be sure to check with a qualified electrician 
or service person if you are in doubt as to whether the outlet is properly 
grounded. If the plug will not fit in the outlet have a qualified electrician or 
service person install the proper plug on to the cord. 

 

This machine is for use on a nominal 220-240 volt circuit with a grounding  plug 

similar to the one in Figure C shown below. Changes to the attachment plug or 

use of adaptors to other plugs must be done in accordance with local 

regulations.          

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 

Parts and Service 

Please contact service personnel or authorized Service Center using 
original replacement parts and accessories for repairs. When calling 
for support please have your Model and Serial Number available 
for faster assistance. 

 

Name Plate 
The Model and Serial Number are located on the lower half of the back 
of the machine near the power plugs and will be required for ordering 
replacement parts.  

 

Unpacking the Machine 
When your new machine is delivered, please carefully inspect both the 
shipping carton and the machine for damages. If damage is evident, 
save both the shipping carton and the machine for inspection by the 
shipping company. Contact the carrier immediately to file a freight claim 
if there is damage. 
 

Summary of Contents for RALLY 220H

Page 1: ...manufactured and assembled in the U S A 3115 Frenchmens Road I Toledo OH 43607 I Ph 419 531 2121 I Fax 419 531 3761 I www nss com OWNER SMANUAL 12GALLONEXTRACTOR RALLY 220 Specifications RALLY 220H RA...

Page 2: ...of fire electrical shock or Injury 5 Preparation 5 Operating Instructions 5 Maintenance Schedule 6 Filter Maintenance 6 Vacuum Stack filters 6 Pump filters In line Filter 6 Trouble shooting 6 Pump doe...

Page 3: ...3 2 4 Pour liquid into front cavity For best results use 100 water Do not use more chemical than directed Over use of chemical clogs jets brass and reducing heater performance Stores into slot below...

Page 4: ...of adapter is employed screw the adapter s extended tab into place with a metal screw However grounding adapters are not approved for use in Canada Again be sure to check the grounding pin for damages...

Page 5: ...s Quick Disconnect QD 3 Plug in power cords Extractor Model Using two separate circuits breakers plug in the grounded power cables as previously instructed using the appropriate grounding techniques...

Page 6: ...using back into base by rotating it TroubleShooting There is no power 1 Plug power cord s in proper outlet s 2 If using two cords make sure each is plugged into a separate circuit 3 Check circuit brea...

Page 7: ...with the furnishing performance use or inability to use the machine The buyer agrees and understands that the remedies provided under this limited warranty are the sole and exclusive remedies availab...

Page 8: ...TABLE 220 TO 500 PSI VACUUM MOTORS 220 220H DUAL PARALLEL 2 STAGE 1 25 HP 500H DUAL PARALLEL 3 STAGE 1 75 HP HEATER 220H 500H 2000 WATT SOUND LEVEL 220 220H 500H 75 Dba ISO 11201 DIMENSIONS HEIGHT 39...

Reviews: