Installing the Spraying Wand Assembly:
Connect the wand assembly to the shut-off valve.
Connect the spray nozzle to the wand assembly.
Tighten all connections to prevent leaks.
Operating the Machine
Priming the pump:
Pull up and push down on the pump handle until
resistance is felt.
Press down handle on shut-off valve to spray solution
tank contents.
Re-pump as required to maintained the desired spray
pressure.
To release the pressure inside the solution tank, pull
out the pressure relief valve. Hold out until the air
escaping the solution tank is finished.
MACHINE MAINTENANCE
Routine maintenance is critical to ensure proper
machine operation and cleaning performance. Perform
all maintenance procedures as follows.
Daily Maintenance
Solution Tank
Empty and clean the solution tank after use.
Inspect all connections. Tighten as required.
Weekly Maintenance (20 hours)
Verify all daily maintenance has been performed.
Inspect the hose for cracks, softness, or brittleness.
Replace if any is found.
Inspect solution tank for any signs of cracks or
deterioration. A machine with signs of cracks or
deterioration should not be used as it could burst
under pressure.
NEVER
attempt to patch any leaks.
Test shut-off valve. Check for clogging or leaks.
Check spray nozzle for clogging or leaks.
Machine Storage
Make sure all pressure is released from the solution
tank.
Remove the pump assembly and store the solution
tank upside down.
The machine should be stored out of direct sunlight in
a warm, dry place.
If exposed to freezing temperatures, make sure to
drain all liquid from the solution tank, pump, hose,
and spraying wand assembly.
Lock the shut-off valve in the “open” position.
Periodically oil the pump assembly by dropping 10-12
drops of light weight oil down the pump rod through
the opening in the cover