background image

13 

 
 
 
 

QUICK OPERATION LIST 
 

1. To enter programming mode:  Press <PAUSE> + 

password

  + <ENTER> .  LED will display “5” if password is correct and remain in 

programming mode, and display “E” if password is incorrect and return to working state. 
 
2. In normal working state, a user can display the GSM signal strength by pressing <5> + <6> + <ENTER> .   “0” means weak, “5” 
means strong.    Press <ENTER> again to return to working state.  
 
3. In alarm state (small “o” displayed in LED), user can input correct password to withdraw the alarm.    The dialer will immediately 
return to a working state, ready to respond to another trigger.  
 
4. Below is a chart for user quick reference.  For detailed explanation, see instructions in this manual. 
 
 

While in programming mode (“5” displayed in the LED), the following functions will work: 

 

Operation 

Function Description 

Display 

PAUSE +

password

ENTER 

 

Edit password, must be 4 
digits

 

After <PAUSE>

”P” appears

; 

After successful entry

 

0

”  appears  and the unit beeps twice 

After failed entry “E” appears 

 

3 + PAUSE

 

Inquire password Input

 

Press <3>

“[ ”appears

 

Press <

PAUSE>

 

password appears

 

E1 + 

phone number

  + 

ENTER + 1 / 2 + ENTER

 

Store/edit the alert recipient 
phone number and alarm 
receiving method

 

Press <E1>

” appears

 

Input phone number

“A” will appear; 

Enter message method (Voice (1) or SMS (2))   
Press <ENTER>  “0” will appear.

 

3 + Ex 

Review phone number and 
alarm receiving method 

Display alarm means  (1 or 2), “A” , then phone number

 

followed by two beeps

 

4 + Ex 

Test the recipient phone 
number and alarm receiving 
method

 

Display “A” if successful 
Display “E”  if failure 
Press <ENTER> to exit test.

 

record voice message Input 

After pressing <1>, “

” will appear

 

When recording is complete, hear

 two beeps  

The recording will playback 

3 + 1 

Play recorded voice message 

“P” will display during play back 

Edit SMS message 

After pressing <2>, send text message to dialer. 
Display “A” if successful 
Display “E”  if failure 

0 + 

Service Provider Contact 

Number

 + ENTER 

Enter Service Provider 
contact number 

Display “A” if successful 

0 + Enter 

Delete Service Provider 
contact number 

Display “A” if successful 

3 + 0 

Review Service Provider 
contact number 

Displays contact number followed by two beeps

  

 

5 +  0/1/2  + ENTER 

 

Program method of stopping 
alert method after receiving it 

Display “A” if successful 

3 + 5 

Review method of stopping 
alert 

Displays 0, 1 or 2 followed by two beeps

  

 

6 + 0-9  + ENTER 

Program number of alert 
retries to attempt 

Display “A” if successful 

3 + 6 

Review number of retries 
programmed 

After enter <3> a “

C

” will display 

After enter <6> the number of retries programmed will 
display 

7 + 1 / 2 + ENTER 

Program duration of alert 
trigger 

Display “A” if successful 

 3 + 7 

Review duration of trigger 
programmed 

Display “1”  or “2” followed by two beeps 

8 +  9 + 1 + 1 + ENTER 

Reset factory default settings 

Display “A” if successful 

ENTER 

Exit programming mode, 
resume normal working state 

 

 
 

 
 

Summary of Contents for E-AVDS-GSM

Page 1: ...atically activates the phone or in this case the E AVDS GSM into which it is inserted SIM cards are available in three standard sizes The first is the size of a credit card 85 60 mm 53 98 mm x 0 76 mm...

Page 2: ...e down on a clean surface The Mini SIM card holder will be facing you 2 Slide the top of the card holder to the right A gap will appear between the top and bottom of the cardholder 3 Flip the top fram...

Page 3: ...sert the card all the way in until it stops 5 Fold the top frame back on top of the bottom The card should set into the same shaped recess in the bottom 6 Slide the top frame to the left to lock the f...

Page 4: ...this configuration a relay closure will trigger an alert state activating the dialer To set the normal relay state to Normally Closed apply the J2 and J1 jumpers to the center and left pins In this c...

Page 5: ...the front circuit board 2 With the screws removed carefully pull the rear circuit board off of the front circuit board Lift the circuit board straight up to separate them 3 Gently lay back the circui...

Page 6: ...ETHODS Connect the cable from the E AVDS GSM to the E xD according to one of the following diagrams Note The attached cable is 27 long but can be extended up to 250 feet with any 3 conductor 22AWG min...

Page 7: ...7...

Page 8: ...E1 through E8 indicators will illuminate while setting the password 5 GSM indicator a LED OFF GSM module power is OFF or doesn t work b 600ms milliseconds ON and 600ms OFF SIM card has not been insert...

Page 9: ...number followed by two beeps To clear and refresh the service provider phone number press 0 and then ENTER The LED will display A to indicate a correct input It will then automatically search for and...

Page 10: ...wer cycling the dialer allow it to restore connection with the service provider and try this procedure again If no SMS message is programmed the default SMS message sent will be DA 911 ALARM 6 Test Pr...

Page 11: ...message was sent successfully It will not follow the programmed number of retries 9 Save and Review Password The dialer supports a 4 digit private password Default password is 0911 To change the defa...

Page 12: ...word is accepted the password will then be displayed the alarm state will be discontinued and two beeps will be heard The E AVDS GSM will return to normal operating mode If the user enters the wrong c...

Page 13: ...one number and alarm receiving method Display alarm means 1 or 2 A then phone number followed by two beeps 4 Ex Test the recipient phone number and alarm receiving method Display A if successful Displ...

Page 14: ...ering duration 0 5 seconds or 3 seconds default is 0 5s Voice recording 20 seconds maximum Phone numbers Up to 8 contact numbers Private password protection 4 digit private password programmable Defau...

Reviews: