13
QUICK OPERATION LIST
1. To enter programming mode: Press <PAUSE> +
password
+ <ENTER> . LED will display “5” if password is correct and remain in
programming mode, and display “E” if password is incorrect and return to working state.
2. In normal working state, a user can display the GSM signal strength by pressing <5> + <6> + <ENTER> . “0” means weak, “5”
means strong. Press <ENTER> again to return to working state.
3. In alarm state (small “o” displayed in LED), user can input correct password to withdraw the alarm. The dialer will immediately
return to a working state, ready to respond to another trigger.
4. Below is a chart for user quick reference. For detailed explanation, see instructions in this manual.
While in programming mode (“5” displayed in the LED), the following functions will work:
Operation
Function Description
Display
PAUSE +
password
+
ENTER
Edit password, must be 4
digits
After <PAUSE>
,
”P” appears
;
After successful entry
“
0
” appears and the unit beeps twice
After failed entry “E” appears
3 + PAUSE
Inquire password Input
Press <3>
,
“[ ”appears
;
Press <
PAUSE>
password appears
E1 +
phone number
+
ENTER + 1 / 2 + ENTER
Store/edit the alert recipient
phone number and alarm
receiving method
Press <E1>
,
“
三
” appears
;
Input phone number
,
“A” will appear;
Enter message method (Voice (1) or SMS (2))
Press <ENTER> “0” will appear.
3 + Ex
Review phone number and
alarm receiving method
Display alarm means (1 or 2), “A” , then phone number
,
followed by two beeps
4 + Ex
Test the recipient phone
number and alarm receiving
method
Display “A” if successful
Display “E” if failure
Press <ENTER> to exit test.
1
record voice message Input
After pressing <1>, “
「
” will appear
;
When recording is complete, hear
two beeps
The recording will playback
3 + 1
Play recorded voice message
“P” will display during play back
2
Edit SMS message
After pressing <2>, send text message to dialer.
Display “A” if successful
Display “E” if failure
0 +
Service Provider Contact
Number
+ ENTER
Enter Service Provider
contact number
Display “A” if successful
0 + Enter
Delete Service Provider
contact number
Display “A” if successful
3 + 0
Review Service Provider
contact number
Displays contact number followed by two beeps
5 + 0/1/2 + ENTER
Program method of stopping
alert method after receiving it
Display “A” if successful
3 + 5
Review method of stopping
alert
Displays 0, 1 or 2 followed by two beeps
6 + 0-9 + ENTER
Program number of alert
retries to attempt
Display “A” if successful
3 + 6
Review number of retries
programmed
After enter <3> a “
C
” will display
After enter <6> the number of retries programmed will
display
7 + 1 / 2 + ENTER
Program duration of alert
trigger
Display “A” if successful
3 + 7
Review duration of trigger
programmed
Display “1” or “2” followed by two beeps
8 + 9 + 1 + 1 + ENTER
Reset factory default settings
Display “A” if successful
ENTER
Exit programming mode,
resume normal working state
Summary of Contents for E-AVDS-GSM