NTI RACKMUX-V17-N-8USBHD-IP RACKMOUNT DRAWER WITH USB KVM SWITCH AND KVM ON IP
51
To program only one device
(CPU port), the corresponding port number must be typed (two-digit number, zero leading, number
between 01 and the last CPU port number, depending on switch size.
To program all devices
, just press
<
a
>
).
The following message will be shown on the screen (it may take about 12 seconds to program each device):
Programming device, please wait...
Device ID: 0x001E
Device successfully programmed!
The bootloader will then ask again for a port number.
To program another port, type the two-digit number of the port,
To exit from this function and the bootloader, press
<x>
.
If <
a
> was pressed instead of a single port number, and all devices were programmed, the message above will be repeated for
each port that was programmed. After all are programmed, unless the switch has 32 CPU ports, the following message will be
shown on the screen
Programming device, please wait...
Device ID: 0x0000
Device failed!
Error Code 1
This is shown because the bootloader continues to look for devices until it has found up to 32 (the maximum number of possible
CPU ports a single UNIMUX can have). If it doesn’t find another port, the procedure will fail and discontinue. On switches with
fewer than 32 ports, this is normal.
To exit from the bootloader, press
<x>
.
Update the Vendor Specific Port Controller Firmware
Updating the vendor specific port controller firmware is similar to updating the HID port controller firmware (described on page 3).
The only differences are that key
<v>
is used to enter this command and the hex file to send will be
unimux-suhd-cpvd
x
-
x.hex
To exit from the bootloader, press
<x>
.