MP2x
60
MP1x
30
MP3x
90
30
60
90
MP1y
MP2y
MP3y
X
(cm)
Y
(cm)
8
Should an error occur during the heating process, the induction heater will automatically stop. The corresponding error will
be displayed on screen. In the case of user error, the display indicates what steps are to be taken to correct the problem.
More information about the types of errors can be found in chapter
ERRORS
.
An induction heater produces an electromagnetic field within a coil to transfer energy
to a workpiece. The table below shows values of the flux density in microTesla (µT).
These measurements can be used as a guide conforming to local regulations regarding
the maximum time exposure to magnetic fields. Different configurations may give
different values. It is impossible to provide values for all combinations as the variety
of bearing types in combination with the different yokes is large.
SAFETY FEATURES
Total 50Hz RMS field for magnetic measurement results. Max. magnetic flux in safe exposure area, according
to the German BG 11 Regulations is 423
µT.
Smart
TEMP
S
M
L
XL
XXL
XXXL
Measurement position (cm)
B-field
total
(µT)
MP1x
81
249
283
454
864
868
MP2x
16
34
74
189
272
370
MP3x
1
11
28
51
143
201
MP1y
156
181
185
458
874
983
MP2y
27
24
78
191
314
416
MP3y
9
9
41
80
156
196
Summary of Contents for SmartTEMP L
Page 1: ...With You www ntn snr com USER MANUAL SmartTEMP S M L XL XL Pivot XXL XXXL...
Page 4: ...4...
Page 31: ...ELECTRICAL DRAWING Start Stop SmartTEMP XL XL Pivot 31...
Page 32: ...ELECTRICAL DRAWING Start Stop SmartTEMP XXL 32...
Page 33: ...ELECTRICAL DRAWING Start Stop SmartTEMP XXXL No contact input No contact input 33...
Page 35: ...NOTES 35...