The HRV will be off. Both fans will be off except on call for heat or cooling. When the
timer is turned ON the fan coil will be in high ventilation mode. The HRV fan and the
main blower will operate in high until the switch is disengaged.
Recommended Seasonal Settings
3.5
Hot, Humid Seasons:
3.2.5
Dehumidistat: 80% or OFF
Thermostat: COOL, Fan Switch ON (continuous)
High speed ventilation will rarely (dehumidistat at 80%) or never (dehumidistat at OFF)
take place. The main blower will usually operate in low speed, circulating cool air
throughout the home and introducing low levels of fresh air and expelling exhaust air
through the ventilation system. The main blower will go into high speed with a call from
the thermostat for cooling. Continuous ventilation is recommended for optimal air
quality.
Additional adjustment:
If high ventilation takes place too often, switch dehumidistat to
OFF.
Cool, Cold Seasons:
3.2.6
Dehumidistat: 40-60%
Thermostat: HEAT, Fan Switch ON (continuous)
High speed ventilation will take place when the dehumidistat set point is exceeded. After
the dehumidistat is satisfied, the main blower will return to low, circulating warm air
throughout the home, while exchanging a small amount of fresh air and exhausting an
equal amount of stale air through the ventilation system. The main blower will go into
high speed with a call from the thermostat for heating, but ventilation rates will remain
low. Continuous ventilation is recommended for optimal air quality.
Adjusting the Dehumidistat setting:
If high speed ventilation takes place too often, raise
the humidity setting on your dehumidistat in 5% steps. If condensation forms on the
windows, the dehumidistat setting should be lowered. The dehumidistat should always
be set higher (15%) than a humidifier if one is installed.
NOTES:
Continuous operation (Fan ON) is recommended when the suite is occupied.
Constant air circulation results in even temperature throughout the suite, from floor to
ceiling, from room to room.
Improved indoor air quality (IAQ): Constant circulation means constant ventilation.
The ECM motor in the unit uses less than 30 watts in circulation mode and is ~ 74%
more efficient than the commonly used PSC motor.