When the thermostat switch is in Fan ON mode the HRV/ERV runs continuously on low
speed, increasing to high speed on call from a timer or optional dehumidistat.
When the thermostat switch is in Fan AUTO mode the HRV/ERV is in standby and will
provide low volume ventilation only on a call for heat, or will provide high speed
ventilation on call from an optional dehumidistat or timer .
Thermostat
3.2
The thermostat should have as a minimum two switches:
A “system switch” controls the mode of operation (heat, cool or off), and a “fan switch”
controls fan operation (On or Auto).
System Switch
3.2.1
System OFF: System does not react to heating or cooling.
System COOL: System is in cooling mode, fan coil comes on when room temperature
rises above set point.
System HEAT: System is in heatign mode, fan coil comes on when room temperature
drops below set point.
Fan Switch
3.2.2
FAN AUTO (intermittent operation): The Enerboss will operate with a call for heating or
cooling or high ventilation from one of the remote controls. Fan operation will cease and
the unit will turn off once the call is satisfied. Low ventilation only occurs on a call for
heat or cool.
FAN ON (continuous): The Enerboss will constantly circulate air on low speed and
ventilate continuously in low volume. On a call for Heating or Cooling unit will go into
high speed cooling/heating and resume low speed after the thermostat is satisfied. On
call from a remote control the unit will go into high speed ventilation and resume low
speed after the remote is satisfied. This is the recommended setting for occupied spaces.
Dehumidistat Control (Optional)
3.3
Excessive ambient humidity can be controlled with an optional wall mounted
dehumidistat. The dehumidistat will initiate high speed ventilation when the humidity
sensor detects humidity in the air around it to be higher than the dehumidistat set point.
In hi-speed ventilation the small exhaust fan will run at high speed and the main fan will
operate at high speed. The Enerboss will cease high speed ventilation when the humidity
sensor detects lower humidity than set point.
Note: Dehumidistat settings do not need to be changed frequently; usually once
when the weather starts to get hot and humid (late spring, early summer), and again
when the weather starts to get cool and dry (late fall, early winter).