Rev 2.3 July 17, 2017
12
No LED: HRV/ERV is OFF
Standby: Unit is in standby, ready for a command
Lo: Unit operates in low speed continuously
20 Lo/40 Standby: Unit cycles between 20 minutes continuous low and 40 minutes standby.
ES-M3
ES Series units are equipped with a recirculation system that will not recycle bathroom air. The
re-circulation function of the ES-M3 enables you to re-circulate air for 40 minutes of every hour.
In addition to ventilating, this control can be used to cycle air when there is no forced air system
to alleviate stratification and dead zones.
Functions:
No LED: HRV/ERV is OFF
Standby: Unit is in standby, ready for a command
Lo: Unit operates in low speed continuously
20 Lo/40 Rec.: Unit cycles between 20 minutes continuous low and 40 minutes recirculation.
Low and circulation cycles are overridden by a high speed signal from another control.
ES-M4
The ES-M4 control offers the simplicity of the ES-M1, with the added convenience of full-time
recirculation mode.
Functions:
No LED: HRV/ERV is OFF
Standby: Unit is in standby, ready for a command
Lo: Unit operates in low speed continuously
Rec.: Unit operates in full-time recirculation with no outdoor air exchange.4
Low and circulation cycles are overridden by a high speed signal from another control.
M4 can only be used with HRV equipped with recirculation capability: NU0103, NU0305, NU0406, NU0508, NU0912, NU1316
with circulation defrost.
Lumnia ES multi-function digital Wall Control with Dehumidista
t
Mounting
MOUNT IN A CENTRAL LOCATION WITHIN THE BUILDING.
FITS A STANDARD 2X3” (NOMINAL) ELECTRICAL WALL BOX (NOT INCLUDED). WHILE YOUR LUMINA WALL CONTROL COMES WITH
A SCREWLESS WALL PLATE, YOU CAN SUBSTITUTE THE FACTORY SUPPLIED WALL PLATE TO MATCH ANY DÉCOR BY USING A FLAT
SCREWDRIVER TO PRY OFF THE ORIGINAL FACE PLATE AND BY REMOVING THE 5 MM SCREWS SECURING FACEPLATE BASE.
DRYWALL ANCHORS MAY BE USED WHERE A WALL BOX IS NOT AVAILABLE.
Wiring
USING A 2 MM FLAT SCREWDRIVER AND 4-CONDUCTOR WIRE, CONNECT THE H/ERV
12 VDC TERMINAL BLOCK TO THE CORRESPONDING TERMINALS LUMINA WALL
CONTROL.
Summary of Contents for NU0103
Page 25: ...Rev 2 3 July 17 2017 25...
Page 26: ...Rev 2 3 July 17 2017 26...
Page 27: ...Rev 2 3 July 17 2017 27...
Page 28: ...Rev 2 3 July 17 2017 28...
Page 29: ...Rev 2 3 July 17 2017 29...
Page 30: ...Rev 2 3 July 17 2017 30...
Page 31: ...Rev 2 3 July 17 2017 31...
Page 32: ...Rev 2 3 July 17 2017 32...
Page 33: ...Rev 2 3 July 17 2017 33...
Page 34: ...Rev 2 3 July 17 2017 34...
Page 35: ...Rev 2 3 July 17 2017 35...
Page 36: ...Rev 2 3 July 17 2017 36...
Page 37: ...Rev 2 3 July 17 2017 37...
Page 38: ...Rev 2 3 July 17 2017 38...