background image

TURBO TANK

Commercial Grade

Portable HVACR Rinsing Sprayer

Nu-Calgon Part No. 4778-0

•  High Velocity Portable HVAC Coil Sprayer
•  Extremely Portable – NO MORE SEARCHING for a Water Connection
•  Optimal 130PSI Water Pressure – Rinse Quickly and Safely 
•  Use with Water Only for Rinsing – Do Not Use with Chemicals
•  High Capacity Lead Acid Rechargeable Battery
•  Improved Brass Hardware for Commercial Grade Durability
•  Perfect for Mini-Splits, Air Handlers, Condensers, and Rooftop Units

Summary of Contents for TURBO TANK

Page 1: ...ely Portable NO MORE SEARCHING for a Water Connection Optimal 130PSI Water Pressure Rinse Quickly and Safely Use with Water Only for Rinsing Do Not Use with Chemicals High Capacity Lead Acid Rechargeable Battery Improved Brass Hardware for Commercial Grade Durability Perfect for Mini Splits Air Handlers Condensers and Rooftop Units ...

Page 2: ...ING INSTRUCTIONS 3 IMPORTANT SAFETY INSTRUCTIONS 3 WARNING TO REDUCE THE RISK OF INJURY 4 LIMITED WARRANTY 5 HOW TO OPERATE 8 AUTOMATIC SHUTOFF 9 GENERAL MAINTENANCE 10 STORING OF THE PORTABLE HVAC SPRAYER 11 FAQ s 12 ...

Page 3: ...Y INSTRUCTIONS When using the Turbo Tank HVACR Rinsing Sprayer these basic precautions should always be followed 1 DO NOT FILL THE TURBO TANK HVACR RINSING SPRAYER WITH ANY NU CALGON COIL CLEANER OR OTHER LIQUID OTHER THAN CLEAN WATER SERIOUS INJURY MAY OCCUR ALSO CLEANERS CAN DAMAGE THE SPRAYER AND WILL VOID WARRANTY 2 ALWAYS APPLY NU CALGON COIL CLEANER SEPARATELY WITH AN AEROSOL CANISTER OR APP...

Page 4: ...ted on the cleaner plate 10 Do not direct the water jet toward the unit itself electrical parts or towards other electrical equipment 11 Do not alter the original diameter of the spray head nozzle 12 DISCHARGE residual pressure before disconnecting the Turbo Tank HVACR Rinsing Sprayer hose 13 Before using the Turbo Tank HVACR Rinsing Sprayer CHECK that the screws are fully tightened and that there...

Page 5: ...to a Nu Calgon authorized wholesaler to initiate the process of repairing or replacing the defective part Typically the sprayer can be remedied in the field do not send back to Nu Calgon without prior authorization The warranty does not include the rechargeable battery usual wear and tear damage resulting from accident or unreasonable use of the product unauthorized repairs or parts that does not ...

Page 6: ...1 16 Self Recoil Hose 4778 20 17 Red Straight Nozzle 4778 13 18 Yellow 15 degree Nozzle 4778 14 19 Indicator Turns from RED TO GREEN when battery is fully charged 20 Mini Split 90º spray wand 4778 10 21 39 inch 90º spray wand available separately 4778 11 22 115VAC to 12VDC Converter available separately 4778 12 Note Sprayer uses a standard Expert Power EXP 1245 12VDC 4 5Ah rechargeable battery Con...

Page 7: ...u Calgon p n 4778 25 or readily available in the market Connect spray nozzle by pulling back on the quick connector and fully inserting the nozzle and fully releasing the quick coupling ALTERNATE MINI SPLIT WAND Connect spray wand by pulling back on the quick connector and fully inserting mini split wand for cleaning the blower and fully releasing the quick coupling ...

Page 8: ...L YOUR TANK 1 Fill the tank with water and cap tank 2 For 12VDC Vehicle Adapter Use Connect to vehicle s 12VDC power port Turn unit on II For Battery Charge battery and switch unit on to I For Optional Convertor Plug into 115VAC power source and plug 12VDC vehicle adapter on sprayer Turn unit on II 3 Turn the power on and run for approximately 30 seconds or until a steady stream of water is presen...

Page 9: ...tomatically activates the motor and pressure is increased once again with a slight delay To ensure the correct automatic shutoff operation the time interval between trigger release and engagement must not be less than 5 10 seconds SHUTTING DOWN YOUR PORTABLE HVAC SPRAYER 1 Place the switch in the OFF position 2 Pull trigger on spray gun to relieve any water pressure in hose or spray gun ...

Page 10: ...d charging the battery fully after each use to ensure the maximum battery life Before the first use charge for 3 4 hours 2 Please note that the battery s charge will reduce over time if stored without use Ideally charge the battery at least once every three months to ensure it remains in a fully charged state 3 Check the battery clamps regularly to ensure they are not loose corroded or defective 4...

Page 11: ... in the mesh storage compartments 4 If the unit must be stored under freezing condition or will be stored for more the 30 days a pump winterizer protector or a non toxic RV anti freeze can be used to prevent freezing and reduce mineral deposits ADD ANTI FREEZE AS FOLLOWS 1 Pour approximately 3 4 gallon 3 liters of RV anti freeze into tank 2 Connect high pressure hose nozzle and power cord 3 Turn u...

Page 12: ...water inlet or outlet is clogged Check if the water inlet filter screen on the base unit is clogged Check if the water hose is bent NOTICE To avoid using up the vehicle s charge please start the engine if you need to use the 12VDC vehicle adapter for more than 30 minutes Specification Pressure PSI 43 5 to 130 5 Volts 12V DC Power 60W Hose 236 inches 6 meters Power Cord 118 inches 3 meters Capabili...

Reviews: