background image

Installation and Maintenance

AXUS Circular Short Cased Axial Flow Fans

3

19

10

. 1

6

. Leaflet Number 671351

6.0 Maintenance

Due to the different periods of operation from the time of

 

installation and varying use, no rigid inspection and 

maintenance periods can be recommended. We suggest

 

therefore that the inspection, and if necessary cleaning/

bearing check should be carried out at regular intervals of a 

maximum of six months.

For routine inspection check the tightness of all nuts, keys,

 

grubscrews and endbolts etc. Remove any build up of dirt

 

or 

dust with a soft brush and ensure that the clearance

 

between the impeller and fan casing has not been 

compromised.

When using a high pressure jet washer, you must maintain a 
minimum of 3 meters from the area being washed

with the 

nozzle at 45

°

 angle to the surface. Operate in a slow 

sweeping motion so as not to spray to

o

 long on one spot.

7.0 Spares

The only components of the fan that could require replacing

 

are the motor or the fan impeller.

When ordering spares please quote the serial number,

 

Order/Arc number, together with a full description of 

the part.

8.0 Extended Storage

General advice is as follows:

Fan products designed for environmental ventilation of 

a completed structure must not be used during site 

construction or the ‘clean-up’ period. Cement and plaster

 

dust is extremely abrasive and can advance bearing wear.

Where fans are to be put in to service for commissioning

 

they must be protected from the airborne contaminants

 

prevalent under construction site conditions.

Where fans are to be put in to ‘normal’ service

 

in a completed

 

or part completed building the end user, tenant, occupier etc.

 

must be informed of the maintenance requirements detailed

 

in the relevant product installation and 

maintenance documents.

Where fans are to be stored or bonded for extensive 

periods either in warehouse, under site conditions or 

in the installed state we make the following additional 

recommendations;

n

 

Motors should be stored at ambient temperatures 

between - 16

o

C and +50

o

C and at relative humidity

(RH) below 90% RH.

n

 

Turn fan and motor shafts at three monthly intervals 

to prevent the brinelling effect on the bearings. Brinelling 

is a flattening or settlement of the shaft in the bearing 

housing.

For extensive storage periods and particularly

 

where  the

 

motors  may  be  exposed  to  high RH levels,  special 

precautions and restart  requirements  may  be  required. 

For  further  advice contact  the  Nuaire  technical help line

 

below.

This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, 
disassembled, or not installed, commissioned and 
maintained in accordance with the details contained in this 
manual and general good practice. 

9

.0  Service  Enquiries

Nuaire  can  assist  you  in all aspects  of  service. Our

 

Technical Support department will be happy to provide 

any

 

assistance required.

Telephone 029 2085 8400

Fax 029 2085 8444

Technical or commercial considerations may,  from time to time, make it necessary to alter the design, performance and 

dimensions of equipment and the right is reserved to make such changes without prior notice.

Reviews: