Leaflet Number 671051 January 2012

Plug the connector into the required sensor module. 

Screw the sensor module into position.

1

2

4

3

5

6

7

Push the repacement cover into the grille front.

Lift out the sensor module wiring connector.

Push out the sensor area cover from the grille.

Fitting Integral Sensors (optional)

Note: Before following the pictorial sequence shown- first

remove the fans front cover grille (2 screws). Release the four

main corner screws and lift out the motor/fan plate assembly.

Remove the electrical cover plate opposite the sensor plate.

Follow the pictorial sequence on this page.

Remove the module plate.

Installation and Maintenance

XS Wall Fan Kits

Unscrew the module plate from motor plate assy.

Summary of Contents for XS6WA

Page 1: ...of the push on impeller for cleaning Upward angled interior grille vanes shield workings from view and downward sloping external vanes throw off rain The fan is IP24 splash proof approved with the mot...

Page 2: ...ood t hei ns i deand out s i dewal l s us h wi t h t he s l eeve Tem por ar y Cr os sbr ace A A Install the sleeve at a slight angle lower to outside INSIDE OUTSIDE 1 2 3 5 4 6 7 8 Remove front grille...

Page 3: ...llaries Also see page 8 for details Wall Fixing Plate and Spacer This thin wall application is best covered using a Window Kit Drg shows a Wall Fixing Plate fixed to the aperture by 4 screws The Windo...

Page 4: ...ied electrician in accordance with the wiring regulations Isolation Before commencing work make sure that the unit is electrically isolated from the mains supply 1 2 3 4 Release the electrical panel f...

Page 5: ...ight Model Watts kg Max Economy XS6WA supply extract 38 20 4 7 Note figures are for extract only Electrical Specification 230V 50Hz Class I Motor thermally protected by overload device Cable 1mm max o...

Page 6: ...cover from the grille Fitting Integral Sensors optional Note Before following the pictorial sequence shown first remove the fans front cover grille 2 screws Release the four main corner screws and li...

Page 7: ...Sensors optional The XS MFC Multi Fan Control provides supply or extract variable speed and automatic or manual switching of several fans if desired see note below The control is best mounted approx 1...

Page 8: ...d with each unit 2 Has not been connected to an unsuitable electrical supply The correct supply voltage is shown on the appliance rating label attached to the unit 3 Has not been modified or repaired...

Reviews: