background image

NTG5110 & NTG5220

      400-115-006-E                    10/11/06                    2/3

This thermostat is pre-programmed with the following default sched-

ule:

It applies to people who wake up at 6:00 AM, leave for work by 9:00 

AM, return home for 5:00 PM and go to sleep at 11:00 PM.
If the pre-programmed schedule fits your lifestyle, skip the following 

section.

First, program your schedule. You can program 4 different periods for 

each day of the week. For each day, enter:

Press

Pgm

 to access the programming mode. Period 1 is 

displayed (

).

Press

Day

 to select the day to be programmed (hold for 

3 seconds to select all days of the week).

NOTE:

It is faster to program the same schedule for the entire week,

then modify the exception days (i.e. Saturday and Sunday).

Press

Hour

 and 

Min

 to program the start time, OR 

Press

Clear

 to clear a time entry.

Press

Pgm

 to select the next period.

Repeat steps 3 and 4 for remaining periods.
When you have completed your programming, press 

Mode/Ret

 to exit the programming mode.

Programming Example: 

This example applies to people who are home during the week. 

Comfort period from 6:00 AM to 11:00 PM (Period 1)

Economy period from 11:00 PM to 6:00 AM (Period 4)

Identical schedule for all days of the week.
Press

Pgm

 to access the programming mode. 

Period 1 is displayed (

).

Press and hold 

Day

 for 3 seconds to select every day 

of the week.
Press

Hour

 to enter 6:00 AM for Period 1.

Press

Pgm

 to select Period 2 (

) and press 

Clear

 to delete 

the time entry (- - : - -).
Press

Pgm

 to select Period 3 (

) and press 

Clear

 to delete 

the time entry (- - : - -).

Press

Pgm

 to select Period 4 ( ) and press 

Hour

 to enter 

11:00 PM.
When you have completed your programming, press 

Mode/Ret

 to exit the programming mode.

To modify the Saturday and Sunday Schedules:

When making modifications, make sure you are in the right period. 
For example, if you are modifying the time for the time you wake up, 

make sure you are in Period 1. 

Press

Pgm

 to select Period 1 (

).

Press

Day

 to select 

SA

 (Saturday).

Press

Hour

 and 

Min

 to enter the time you wake up on week-

ends. 
Press

Pgm

 to select Period 4 ( ).

Press

Hour

 and 

Min

 to enter the time you go to sleep on week-

ends.
Repeat above steps for Sunday (

SU

).

Press

Mode/Ret

 to exit programming mode.

NOTE: To avoid damaging your floor, follow your floor supplier’s rec-

ommendations regarding the minimum and maximum floor tempera-

ture limits.

The minimum and maximum floor temperature limits are 5 °C (41 °F)

and 28 °C (82 °F) by default. To modify these limits, proceed as fol-

lows:

Switch the thermostat to Standby.
Press and hold the   button.
Switch the thermostat back to On.
Release the   button when the minimum temperature 
limit (

FL:LO

) appears.

Set the minimum temperature limit using the     
buttons.
Press the   button to display the maximum 
temperature limit (

FL:HI

).

Set the maximum temperature limit using the     buttons.
Press

Mode/Ret

 to exit.

Temporary or Permanent Temperature Bypass:

This operation allows you to temporarily modify the floor temperature 

while you are in the Automatic mode. 

Simply press    to select the desired temperature, or 

or

button to select the Comfort or Economy settings you have pro-

grammed. 

This  temperature  will  be  maintained  until  the  beginning  of  the

next programmed schedule. 

You  can  also  switch  to  the  Vacation  setting  for  a  prolonged

absence by pressing  . In that case, the temperature bypass is

permanent. 

To return to the normal operating mode, press 

Mode/Ret

.

If you wish to immediately return to the programmed settings, press 

Mode/Ret

.

Default Schedule

5.

Periods

MON

TUE

WED

THU

FRI

SAT

SUN

88°F

6 AM

6 AM

6 AM

6 AM

6 AM

6 AM

6 AM

73°F

9 AM

9 AM

9 AM

9 AM

9 AM

--:--

--:--

88°F

5 PM

5 PM

5 PM

5 PM

5 PM

--:--

--:--

73°F 11 PM 11 PM 11 PM 11 PM 11 PM 11 PM 11 PM

Modify the Default Schedule

6.

Time you wake up (Period 1)
Time you leave for work (Period 2)
Time you return home (Period 3)
Time you go to bed (Period 4)

Floor Temperature Limits (AF mode only)

7.

Special Features

8.

Summary of Contents for NTG5110

Page 1: ... displayed app 3 seconds Press the Mode Ret button to exit this function and return to the normal operating mode Description 1 A mode controls the ambient air temperature F mode controls the floor temperature using an external temperature sensor AF mode controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor Operating Modes 2 ...

Page 2: ... time you wake up make sure you are in Period 1 Press Pgm to select Period 1 Press Day to select SA Saturday Press Hour and Min to enter the time you wake up on week ends Press Pgm to select Period 4 Press Hour and Min to enter the time you go to sleep on week ends Repeat above steps for Sunday SU Press Mode Ret to exit programming mode NOTE To avoid damaging your floor follow your floor supplier ...

Page 3: ...ches to your preferences Put the faceplate back on the thermostat Secure the thermostat with the screw Display range 32 F to 158 F 0 C to 70 C Ambient setpoint range A AF models 40 F 86 F 5 C to 30 C Floor setpoint range F model 40 F 104 F 5 C to 40 C Floor limit range AF model 40 F 104 F 5 C to 40 C NUHEAT INDUSTRIES ONE 1 YEAR LIMITED WARRANTY This product is guaranteed against workmanship defec...

Page 4: ...l conditions The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment NUHEAT cannot be held liable for related or random damages following the installation of this product The defective product a...

Page 5: ...ranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment NUHEAT cannot be held liable for related or random damages following the installation of this product The defective product as well as the purcha...

Reviews: