background image

Warning! Read instructions before using the machine

Owner Instructions

SSIVD 1800 DH

SSIVD 1800 PH

SSIVD 1800 AP

SWARF ENGINEERING VACUUM

www.numatic.co.uk

Summary of Contents for SSIVD 1800 AP

Page 1: ...Warning Read instructions before using the machine Owner Instructions SSIVD 1800 DH SSIVD 1800 PH SSIVD 1800 AP SWARF ENGINEERING VACUUM www numatic co uk...

Page 2: ...ined into a suitable environmentally approved collection point or returned to the cutting machine for further use SSIVD 1800 PH Pump hose The vacuum is fitted with a pump allowing the operator to remo...

Page 3: ...e vacuum Assemble the wand floor tool and hose Fit the reducer adaptor to the cyclonic inlet and connect the suction hose Storage of DH PH hose DH PH hose closure Open Closed Connection of AP hose 10...

Page 4: ...mp Hose Once plugged in to the power supply proceed to turn on the blue switch fitted to the handle of the head assembly this activates the vac motor The vacuum is now ready to use PH version Pumped H...

Page 5: ...t to activate the micro switch fitted in the pump float The vacuum can then be drained into a suitable environmentally approved collection point or returned to the cutting machine for further use Drai...

Page 6: ...sembly Release the two head retaining clips Remove the head assembly from the vacuum body Lift out the cartridge filter and replace if necessary Use genuine Numatic replacment filter part No 207124 Ma...

Page 7: ...lifting the basket as it may be heavy Whilst the machine is apart it is a good time to clean the cyclonic inlet and check the bottom sealing gasket Remove the three toggles that hold the plastic adapt...

Page 8: ...d collected and sent for recovery in an environmentally friendly manner Ear Protection Safety Footwear Head Protection Safety Gloves Dust Allergens Protection Eye Protection Protective Clothing Hi Vis...

Page 9: ...ld function normally Liquid ejected from the machine could be hazardous as a result of its temperature pressure or chemical content This machine is not suitable for the collection of biological hazard...

Page 10: ...vacuum motor will change Remove the power head and float cage and empty the waste out of the container if the container is empty check that the floor tool wands and hose are not blocked After use alw...

Page 11: ...11 T 01460 269401 EU Declaration of Conformity Warranty...

Page 12: ...05 11 98 42 16 0 www numatic de Numatic International SAS 13 17 rue du Valengelier 77500 CHELLES FRANCE Tel 01 64 72 61 61 www numatic fr BeNeLux Distribution Numatic International BV Postbus 101 2400...