T (+ 44) 01460 68600
Battery care
TO ENSURE YOUR MACHINE REMAINS AT ITS MAXIMUM EFFICIENCY
AND PROLONG YOUR BATTERY LIFE, PLEASE FOLLOW THE SIMPLE STEPS BELOW:
!
!
Signal (LED)
Meaning
Red LED on
First phase (constant current mode)
Orange LED on
Second phase (constant voltage mode)
Green LED on
Third phase (constant voltage mode) charge complete
Red LED flashing
followed by Pause
Cooling fan locked > 1 flash between pause
Over voltage protection / Output short circuit / Battery reverse polarity > 2 flashes between pause
Over temperature protection > 3 flashes between pause
Charge time has exceeded 16 hrs during phase 1 or 2 > 4 flashes between pause
Charging light sequence
UNDER NORMAL DAILY USAGE:
Re-charge the machine FULLY after each use regardless of machine operation time.
Do not leave the machine in a discharged state.
Periodically inspect the battery connections for tightness and corrosion.
Under abnormal use;
i.e. leaving the machine without charging for a period of time, we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days or more, then batteries
must be fully charged and battery fuse removed using the maxi fuse-puller provided, prior
to this period.
Batteries should be recharged every three months.
Charge fully the day before you start using the
machine again.