ALWAYS ENSURE THAT THE POWER SUPPLY IS DISCONNECTED PRIOR TO ANY
MAINTENANCE.
To change the floor tool, firstly swing the floor tool clear of the
machine (Fig 38).
Undo the two floor tool retaining knobs (Fig 39).
Unscrew the four knobs securing the blade holder (Fig 40).
Remove the blade holder (Fig 41).
Replace the Squeegee blades using (606261) replacement blade set (Fig 42), fitting the blades on to the moulded
location lugs.
Refit the blade holder, retain using the two outer knobs (Fig 46)
Refitting the Floor Tool Blades
Ensure the slotted blade goes to the front of the
floor tool (Fig 47).
Refit the floor tool using the two central knobs to
the floor tool.
Refer to Page 5 for fitting instructions.
1. Floor tool main body
2. Blade carrier
3. Rear blade
4. Front blade (slotted)
5. Retaining Knobs x 4
1
2
3
5
4
Fig 44
Fig 45
Fig 46
Fig 47
Note:
The blades are designed to be reversible,
thus extending their useful working life.
Use Genuine NUMATIC spare parts.
use Replacement Blade Set (606261)