Sentronic
D
Installation
Manual
2. Electrical Connection
5-pin M12 female connector
(view on soldered side)
250 Ohm at cur-
rent setpoint
Valve
M12 connector
+24V supply voltage
Supply voltage GND
Setpoint GND
(only for 6-wire cable)
Setpoint
0-10V
(or 0-20 / 4-20mA)
Feedback
0-10V
(or 0-20 / 4-20mA)
Control
Analog output:
Only at current output:
max. 500 ohm
Digital output:
PNP when setpoint is reached
(setpoint=feedback)
Inductive
load
M4 connection on valve body
1) The valve must only be supplied with 24V DC at a tolerance of +15%/-10% and a max. ripple of 10% (no supply via
diode bridge). Overvoltage or a ripple rate exceeding these tolerances can damage the electronics.
2) The max. current at the digital output is 200 mA/4.8W (PNP output). The output is protected against short circuit and
overload.
3) If a relay (inductive load) is connected to the digital output, a freewheel diode or a varistor must be used.
4) A shielded cable must be used for protection against interference and EMC.
5) The valve body must be grounded with the earthing terminal PE (dia. M4)
Connector housing
Shield
=200mA max./4.8W
Connector Pin Out
Command signal: View on soldered side of female connector
2
1
4
3
5
PIN
Description
1
+24 VDC Supply
2
Command Signal
3
+0 VDC Common (Supply)
+0 VDC Common (Command Signal)*
4
Analog output (feedback)
5
Digital output (pressure switch)
Body
EMC shield
*A 6-wire cable with separate common for the command signal is used for cable
lengths over 2 m to minimize the voltage drop for the command signal.