background image

09

08

HTTP://WWW.NUMAXTOOLS.COM        1-888-669-5672

HTTP://WWW.NUMAXTOOLS.COM        1-888-669-5672

MODEL: S18GLCNDH

MODEL: S18GLCNDH

Only use those fasteners recommended 
for  use  with  this  tool.  Fasteners  not 
identified  for  use  with  this  tool  by  the 
tool manufacturer are able to result in a 
risk of injury to persons or tool damage 
when used in this tool.

 WARNING:

!

The  tool  may  fire  when  it  is  first 
connected  to  the  air  source.  Always 
connect  the  tool  to  the  air  source 
before  loading  fasteners  to  prevent 
injury  from  unintended  cycling. 
Always make sure the tool's magazine 
is  empty  at  the  beginning  of  each 
work session, before connecting to an 
air source.

 WARNING:

!

UNLOADING L CLEATS

Disconnect the tool from the air source.
Pull back the pusher, pressing bypass lever 
of  the  pusher  allow  to  pusher  to  bypass 
nails  and  slowly  allow  pusher  to  return  to 
nose of the tool.
Slide the fastener to the rear magazine.

1.
2.

3.

Press bypass lever

SLIDE 

FORWA

RD

CHANGING THE FOOT PLATE

The tool is equipped with a factory pre-installed 
9/16  in.  to  5/8  in.  foot  plate  (G).  and  an 
additional uninstalled 3/4 in. and 3/8 in. to 1/2 in. 
foot plate and 7/16 in. flooring shim.
To change the plate:

Disconnect the tool from the air source.
Empty the magazine completely.
Fire the tool into a piece of scrap wood to 
ensure  there  is  no  compressed  air  or 
fasteners left in the tool. 
Set the tool on its side to expose the four 
screws (H).
Remove  the  four  screws  (H),  then  remove 
the foot plate.
Align   the   four   screw   holes   in   the 
replacement  foot  plate  with  the  four 
threaded mounting holes.
Using  the  four  screws  you  removed  just 
now, secure the replacement foot plate to 
the tool.
Ensure the correct Foot Plate is installed by 
firing  into  a  scrap  piece  of  flooring  and 
checking for proper fastener placement.

1.
2.
3.

4.

5.

6.

7.

8.

Disconnect  the  tool  from  the  air  source 
whenever changing the foot plate. 
Make  sure  there  is  no  fastener  in  the 
magazine before changing the foot plate.

 WARNING:

!

Screws(H)

Foot plate(G)

ADJUSTING THE FRONT FOOT

The  tool  is  equipped  with  an  adjustable  front 
foot, can be adjusted for 3/8 in. to 3/4 in. wood 
floors. This tool is shipped out set for 5/8 inch & 
9/16 inch wood floor.

To adjust the front foot (I):

Disconnect the tool from the air source.
Empty the magazine completely.
Fire the tool into a piece of scrap wood to 
ensure.  there  is  no  compressed  air  or 
fasteners left in the tool.
Set the tool on its side to expose the two 
Bolts(J) and two Small Plates (K).
Loosen  these  two  Bolts  (J)  to  move  the 
Front  Foot  (I)  in  the  range  of  the  Adjust 
Groove (L).
Adjust the proper position of the Front Foot 
(I)  according  to  the  actual  thickness  of 
wood floors and then lock tightly these two 
Bolts (J).
Ensure  the  correct  front  foot  set  for  the 
wood  floor  by  firing  into  a  scrap  piece  of 
flooring  and  checking  for  proper  fastener 
placement.

Two Bolts (J)

Small plate (K)

Adjust groove (L)

1.
2.
3.

4.

5.

6.

7.

Disconnect  the  tool  from  the  air 
source  whenever  changing  the  foot 
plate. Make sure there is no fastener 
in the magazine before changing the 
foot plate.

 WARNING:

!

Front foot (I)

SETTING THE AIR PRESSURE

The  amount  of  air  pressure  required 
depends on the size of the fasteners and the 
workpiece material. 
Begin testing the depth of drive by driving a 
test  nail  into  the  same  type  of  workpiece 
material used for the actual job.
Drive a test fastener with the air pressure set 
at 90-95 psi. 
Raise  or  lower  the  air  pressure  to  find  the 
lowest setting that will perform the job with 
consistent results.

1.

2.

3.

4.

OPERATING THE TOOL

Attach the tool to the air source. Start your 
compressor  and  check  the  pressure, 
making sure it is set between 70-115 psi. Do 
not exceed the maximum 115 psi.
Hold the hand grip (N) securely and press 
the foot plate (G) to the work surface. Make 
sure  the  plate  is  over  the  fastener  target 
position. 
Press down firmly so that the foot plate (G) 
is firmly contacting the work surface. Then, 
using the mallet packed with the tool, strike 
the  hammer  cap  (M)  firmly  to  drive  the 
fastener into work surface. Lift the tool off 
the work surface. Repeat this process until 
the job is completed.

1.

2.

3.

Tongue and groove flooring

The flooring nailer is designed for tongue and 
groove flooring only. Place the nailer flush onto 
the  work  surface  and  ensure  that  you  are 
striking at the tongue of the hardwood floor. 

Summary of Contents for S18GLCNDH

Page 1: ...W NUMAXTOOLS COM 1 888 669 5672 PRIME GLOBAL PRODUCTS INC SAVE THIS MANUAL FOR FUTURE REFERENCE WARNING Failure to follow warnings could result in DEATH OR SERIOUS INJURY S18GLCNDH V1 03 19 18 GAUGE L...

Page 2: ...ION 65 This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65...

Page 3: ...e the tool as a hammer Never use this tool in a manner that could cause a fastener to be directed toward anything other than the workpiece TOOL USE AND CARE TOOL SERVICE Only use accessories that are...

Page 4: ...sing this tool make sure the arm part and the main body part are screwed together tightly Failure to do so could result in possible serious personal injury WARNING LOADING L CLEATS Nut B Hex Bolt Hand...

Page 5: ...foot can be adjusted for 3 8 in to 3 4 in wood floors This tool is shipped out set for 5 8 inch 9 16 inch wood floor To adjust the front foot I Disconnect the tool from the air source Empty the magaz...

Page 6: ...riginal position See figure 7 Replace the Nose Guide P and Nose Bolts O See figure 8 Reconnect tool to the air source then reload the tool with fasteners Press the tool against a piece of wood and tes...

Page 7: ...h can rust or gum up internal parts of the tool Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails or 1...

Page 8: ...irt inside nailer 1 Low air pressure 2 Broken Driving Blade 3 Nail hit hard surface 4 Piston O ring worn out 5 Worn out nose 1 Air supply fittings loose 2 Excess air pressure blew out seals 3 Cracked...

Page 9: ...MODEL S18GLCNDH MODEL S18GLCNDH THESE WARRANTIES ARE SUBJECT TO CHANGE WITHOUT NOTICE 17 16 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 HTTP WWW NUMAXTOOLS COM 1 888 669 5672...

Reviews: