09
08
HTTP://WWW.NUMAXTOOLS.COM 1-888-669-5672
HTTP://WWW.NUMAXTOOLS.COM 1-888-669-5672
MODEL: S18GLCNDH
MODEL: S18GLCNDH
Only use those fasteners recommended
for use with this tool. Fasteners not
identified for use with this tool by the
tool manufacturer are able to result in a
risk of injury to persons or tool damage
when used in this tool.
WARNING:
!
The tool may fire when it is first
connected to the air source. Always
connect the tool to the air source
before loading fasteners to prevent
injury from unintended cycling.
Always make sure the tool's magazine
is empty at the beginning of each
work session, before connecting to an
air source.
WARNING:
!
UNLOADING L CLEATS
Disconnect the tool from the air source.
Pull back the pusher, pressing bypass lever
of the pusher allow to pusher to bypass
nails and slowly allow pusher to return to
nose of the tool.
Slide the fastener to the rear magazine.
1.
2.
3.
Press bypass lever
SLIDE
FORWA
RD
CHANGING THE FOOT PLATE
The tool is equipped with a factory pre-installed
9/16 in. to 5/8 in. foot plate (G). and an
additional uninstalled 3/4 in. and 3/8 in. to 1/2 in.
foot plate and 7/16 in. flooring shim.
To change the plate:
Disconnect the tool from the air source.
Empty the magazine completely.
Fire the tool into a piece of scrap wood to
ensure there is no compressed air or
fasteners left in the tool.
Set the tool on its side to expose the four
screws (H).
Remove the four screws (H), then remove
the foot plate.
Align the four screw holes in the
replacement foot plate with the four
threaded mounting holes.
Using the four screws you removed just
now, secure the replacement foot plate to
the tool.
Ensure the correct Foot Plate is installed by
firing into a scrap piece of flooring and
checking for proper fastener placement.
1.
2.
3.
4.
5.
6.
7.
8.
Disconnect the tool from the air source
whenever changing the foot plate.
Make sure there is no fastener in the
magazine before changing the foot plate.
WARNING:
!
Screws(H)
Foot plate(G)
ADJUSTING THE FRONT FOOT
The tool is equipped with an adjustable front
foot, can be adjusted for 3/8 in. to 3/4 in. wood
floors. This tool is shipped out set for 5/8 inch &
9/16 inch wood floor.
To adjust the front foot (I):
Disconnect the tool from the air source.
Empty the magazine completely.
Fire the tool into a piece of scrap wood to
ensure. there is no compressed air or
fasteners left in the tool.
Set the tool on its side to expose the two
Bolts(J) and two Small Plates (K).
Loosen these two Bolts (J) to move the
Front Foot (I) in the range of the Adjust
Groove (L).
Adjust the proper position of the Front Foot
(I) according to the actual thickness of
wood floors and then lock tightly these two
Bolts (J).
Ensure the correct front foot set for the
wood floor by firing into a scrap piece of
flooring and checking for proper fastener
placement.
Two Bolts (J)
Small plate (K)
Adjust groove (L)
1.
2.
3.
4.
5.
6.
7.
Disconnect the tool from the air
source whenever changing the foot
plate. Make sure there is no fastener
in the magazine before changing the
foot plate.
WARNING:
!
Front foot (I)
SETTING THE AIR PRESSURE
The amount of air pressure required
depends on the size of the fasteners and the
workpiece material.
Begin testing the depth of drive by driving a
test nail into the same type of workpiece
material used for the actual job.
Drive a test fastener with the air pressure set
at 90-95 psi.
Raise or lower the air pressure to find the
lowest setting that will perform the job with
consistent results.
1.
2.
3.
4.
OPERATING THE TOOL
Attach the tool to the air source. Start your
compressor and check the pressure,
making sure it is set between 70-115 psi. Do
not exceed the maximum 115 psi.
Hold the hand grip (N) securely and press
the foot plate (G) to the work surface. Make
sure the plate is over the fastener target
position.
Press down firmly so that the foot plate (G)
is firmly contacting the work surface. Then,
using the mallet packed with the tool, strike
the hammer cap (M) firmly to drive the
fastener into work surface. Lift the tool off
the work surface. Repeat this process until
the job is completed.
1.
2.
3.
Tongue and groove flooring
The flooring nailer is designed for tongue and
groove flooring only. Place the nailer flush onto
the work surface and ensure that you are
striking at the tongue of the hardwood floor.