Repairs or alterations have been made, or attempted, by others, and/or the unauthorized use of 
non-conforming parts or accessories.
Repairs are required due to normal wear and tear. 
The  Nail  Gun  has  been  abused,  misused,  improperly  maintained  or  operated,  including:  the 
failure to use clean, dry, regulated compressed air at the recommended pressure; accidents 
caused by use of the 

 Product after partial failure.

Numax

The 

 Product is used commercially in assembly lines or production lines. The 

 

Numax

Numax

Product  is  intended  for  use  by  individuals  and  these  warranties  do  not  extend  to  such 
commercial uses.

Stop using tool immediately if any of the following problems occur. Serious personal injury 
could result. Any repairs or replacements must be done by a qualified service person or an 
authorized service center.

 WARNING:

!

Air leaking at trigger 
valve area. 

O-rings in trigger valve housing are
damaged

.

Replace O-rings. Check operation
 of Work Contact Element(WCE).

Air leaking between 
housing and nose.

1.Loose screws in housing.
2.Damaged O-rings.
3.Damaged to bumper.

1.Tighten screws.
2.Replace O-rings.
3.Replace bumper.

Air leaking between 
housing and cap.

1.Loose screws.
2.Damaged gasket. 

1.Tighten screws.
2.Replace gasket.

1.Replace bumper.
2.Clean drive channel.
3.Clean magazine.

4.Replace spring.
5.Check fitting, hose or compressor.
6.Replace and lubricate O-rings.

7.Replace O-rings.
8.Tighten screws and fittings.
9.Replace gasket.

1.Worn bumper.
2.Dirt in nose piece.
3.Dirt or damage prevent fasteners or 
 

pusher from moving freely in magazine.

4.Damaged pusher spring.
5.Inadequate air flow to tool.
6.Worn O-ring on piston or lack 
   of lubrication.
7.Damaged O-ring on trigger valve.
8.Air leaks.
9.Cap seal leaking.

Tool skips driving 
fastener.

PROBLEMS

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

1.Lubricate nailer.
2.Replace spring.
3.Replace damaged internal parts.

1.Tool not lubricated sufficiently.
2.Broken spring in cylinder cap.
3.Exhaust port in cap is blocked.

Tool runs slow or has 
loss of power.

1.Replace guide.
2.Use only recommended fasteners.
3.Replace with undamaged fasteners.
4.Tighten screws.
5.Replace drive.

1.Guide on driver is worn.
2.Fasteners are not correct size.
3.Fasteners are bent.
4.Magazine or nose screws are loose.
5.Drive is damaged. 

Fasteners are jammed
in tool.

Use only Numax authorized repair parts. For questions please call 1-888-669-5672 or visit our 
website at http://www.numaxtools.com

 WARNING:

!

WEARABLE PARTS

Repair parts can be ordered from our website: http://www.

tools.com

numax

Summary of Contents for SFR2890

Page 1: ...AL FOR FUTURE REFERENCE WARNING Failure to follow warnings could result in DEATH OR SERIOUS INJURY 28 3 1 2 CLIPPED HEAD FRAMING NAILER 28 3 1 2 CLIPPED HEAD FRAMING NAILER 28 3 1 2 CLIPPED HEAD FRAMING NAILER IMNSFR2890 V1 04 18 HTTP WWW NUMAXTOOLS COM 1 888 669 5672 PRIME GLOBAL PRODUCTS INC ...

Page 2: ...if you are producing metal filings or wood chips Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your long hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Stay alert watch what you are doing and use common sense when operating a power tool Do not use tool while tired or under the influence of drugs alcohol...

Page 3: ...rd yourself or anyone whether it contains fasteners or not Wash hands after handling This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Know this tool Read manual carefully learn its applications and limitations as well as the specific potential hazards related to this tool O n l y u s e f a s t e n e r...

Page 4: ...ners when any one of the operating controls is activated Never place a hand or any part of body in fastener discharge area of tool Never point the tool at anyone Do not pull the trigger or depress the workpiece contact as accidental actuation may occur possibly causing injury The warnings and precautions discussed above cannot cover all possible conditions and situations that may occur It must be ...

Page 5: ...source Turn the depth wheel left or right to change the driving depth Reconnect the tool to the air source Drive a test nail after each adjustment until the desired depth is set Turn the adjustment knob clockwise Turn the adjustment knob count clockwise Too Deep Adjustment wheel D Flush Flush Too Shallow Adjustment wheel D It is advisable to test the depth on a scrap workpiece to determine the req...

Page 6: ... to the air source run tool briefly Wipe off any excess oil from the cap exhaust RECOMMENDED HOOKUP The air compressor must be able to maintain a minimum of 70 psi when the tool is being used An inadequate air supply can cause a loss of power and inconsistent driving An oiler can be used to provide oil circulation through the tool A filter can be used to remove liquid and solid impurities which ca...

Page 7: ...r 1 Tighten screws 2 Replace O rings 3 Replace bumper Air leaking between housing and cap 1 Loose screws 2 Damaged gasket 1 Tighten screws 2 Replace gasket 1 Replace bumper 2 Clean drive channel 3 Clean magazine 4 Replace spring 5 Check fitting hose or compressor 6 Replace and lubricate O rings 7 Replace O rings 8 Tighten screws and fittings 9 Replace gasket 1 Worn bumper 2 Dirt in nose piece 3 Di...

Reviews: