Programming
You can program the module using the LED keypad or the LCD keypad. To program the module using the
LED keypad, do the following:
Enter program mode
To enter program mode, press
* 8
. The Stay, Chime, Exit, Bypass, and Cancel LEDs on the keypad will flash.
Enter the “go to program code”. The factory default is
9 7 1 3
. If the code is valid, the Service LED on the
keypad will flash and the five function LEDs will illuminate steady. You are now in program mode and can
select the module to program.
Select the module to program
To select the module to program, press
7 6 #
(the address of this GSM module). The Armed LED on the
keypad will illuminate while it is waiting for a programming location to be entered.
Factory default the module
To return the module to factory defaults, press
9 1 0 #
. The keypad will beep three times indicating that
loading is in progress. Remember you will erase any values you may have entered previously.
Programming a location
Once the number of the module to be programmed has been entered, the Armed LED on the keypad will
illuminate while it is waiting for a programming location to be entered.
Note:
If an attempt is made to program an invalid entry for a particular segment, the keypad sounder will emit a triple
error beep, and remain in that segment waiting for a valid entry.
To enter a location, enter the location number (1 to 13) and press
#
. The Armed LED will flash. If the location
is valid, the Armed LED will extinguish, the Ready LED will illuminate, and the zone LEDs will show the
data for the first segment of this location.
To change location data, enter the changed data. The Ready LED will flash to indicate a data change in
progress and will continue until the data is saved. Press
*
to save the new data. The keypad will advance to
the next segment and display its data. These steps are repeated until the last segment is reached.
To exit a location, press
#
. The Ready LED will extinguish. The Armed LED will illuminate waiting for a
new programming location to be entered.
To review the data, enter the location number and press
#
. The Armed LED will flash. If the location number
is valid, the Armed LED will extinguish, the Ready LED will illuminate, and the zone LEDs will show the
binary data for the first segment of this location. Press * to display the next segment data. Each time you press
*, the data of the next segment will be displayed for review.
Exit program mode
Press
Exit
to exit this programming level. Press
Exit
a second time to completely exit programming.