Location 0, programming the mode
This location has five numeric data segments. This location contains the system identification number (SID).
Factory default is 0-0-0-0-0 for AutoSID.
Note:
If manually entering an SID, use leading zeroes.
Location 1, feature selection
This location has four segments. Segment 1 contains the options to be programmed for the functioning of this
module. Factory default for all Segment 1 options is off.
Table 5
describes the options
Table 5. Segment 1 options
Segment 2 programs host acknowledgement requirements. Factory default for all Segment 2 options is off.
Table 6
describes the options.
Table 6. Segment 2 options
1
Daily test will be performed 24 hours (± 10 minutes) from time this option is programmed.
2
Weekly test will be performed 168 hours (± 10 minutes) from time this option is programmed.
3
Some older SIA DCS compatible receivers may not support the use of area (partition) modifiers. In such cases, the area
modifier must be disabled (Option 8 on).
Segments 3 and 4 are reserved for future use.
Option
Description
On
Off
1
Format
SIA
Contact ID
2
Test signal
Daily
1
Weekly
2
3
System preference
Use A or B side only
No preference
4
B side preference
B side (if option 3 is on)
A side
5
Alternate MIN
Disabled
Enabled
6
Disable cellular service LEDs
Disabled
Enabled
7
Enable tamper switch
Enabled
Disabled
8
Disable SIA DCS area modifier
3
Disabled
Enabled
Options
Description
On
Off
1
Central station messages
Enabled
Disabled
2
E-mail messages
Enabled
Disabled
3
Pager messages
Enabled
Disabled
4
Periodic test signals
Enabled
Disabled
5 to 8
Reserved for future use.