DSP LASER AP with MCS
a
Error Antipanic Wiring: the signals relevant to antipanic (INP1 and INP2) are not
congruent. Verify the connection with OUTP1 and OUTP2 and make sure that, with
antipanic pressed, is INP1 OFF and INP2 OFF while, with antipanic not pressed,
INP1 is ON and INP2 is ON.
Note. Once verified and restored the connection of the antipanic chain, open the
chain (pressing the third position of the pedal) and close again the chain (releasing
the pedal) to clear this alarm.
b
Button Emergency Reset Pressed: the emergency reset button has been reset.
Release the button and the downstroke pedal. If this error persists, verify the
connection (ING3).
c
Button Rear Guard Reset Pressed: the rear guard reset button has been pressed.
Release the button and the downstroke pedal. If this error persists, verify the
connection (ING4).
d
Cycle Anti-repetition: a bending cycle has been executed without releasing the
downstroke pedal. Release the pedal to execute a new bending cycle.
e
Alarm Lower Clamps Open: the lower clamps are open. The press cannot close.
Close the clamps to restore the correct operation.
f
Error Lower Clamps: the signals relevant to the upper clamps are not correct. Verify
the operation of the control signal (ING6) and of the pressure switch (INS24) and
their connection to MCS.
g
Error Monitor6: The monitor relevant to solenoid valve driven by OUTS6 has given a
wrong output. Verify the correct operation of the monitor and the connection of the
monitor to MCS (INS17).
h
Error Monitor7: The monitor relevant to solenoid valve driven by OUTS7 has given a
wrong output. Verify the correct operation of the monitor and the connection of the
monitor to MCS (INS20).
i
Error Modes: the mode selector is not correctly connected. Verify the selector and the
connection to INS1 and INS2.
j
System Error: call the service.
k
Error Encoder: a movement has been command to MCS but the encoders have not
detected any movement. Verify that the press is not at PMS or PMI and verify the
connection and the operation of the encoders.
Note. Press the emergency reset button to clear this alarm.
l
Downstroke Anti-repetition: during the downstroke, CNC has command a stop and a
new downstroke without the downstroke pedal has been released. Release the
Downstroke pedal to restore the system.
m
Error RS232 reception: RS232 communication with CNC does not take place
correctly. Verify that CNC is ON and operating and that the connection cable
between CNC and MCS is properly connected.
n
Error Robot request: The procedure for the robot function activation is not correct.
Verify that CNC tranmits the robot request command and that the selector connected
to INS22 is ON if you wish to activate the robot mode or verify that CNC does not
transmit the robot request command to MCS and that the selector connected to IN22
is OFF.
p
Verify Monitor1 at the end of the bending cycle.
q
Verify Monitor2 at the end of the bending cycle.
r
Verify Monitor3 at the end of the bending cycle.
s
Verify Monitor4 at the end of the bending cycle.