DSP LASER AP with MCS
6.
Legend
TERM
MEANING
HIGH SPEED
Speed of the mobile part of the machine when closing or approaching the
sheet
ANTIPANIC
Alarm generated by the pressure of the third position of the downstroke
pedal
BEND AXIS
Axis of the section perpendicular to the punch length
AUTOMUTING
Automatic inhibition of a detection area
LOW SPEED
Speed of the mobile part of the machine, when closing or approaching the
sheet, equal to or lower than 10 mm/s
BLANKING
Function inhibiting part of the detection area
DETECTION
CAPACITY
Minimum size of the test piece capable to be detected
COLLIMATION
Procedure allowing the alignment of the laser beam generated by TX to
the RX receiving area
SAFETY DISTANCE
Distance between the punch tip and the lower edge of the detection area,
equal to the sum of the maximum stop distance and 5 mm
DSP LASER AP
Name of the device charged to monitor the front part of the press
ESPE
Electro-Sensitive Protective Equipment
INHIBITION
Automatic and temporary interruption of the safety functions executed by
the safety parts of the control system
BENDING LINE
Line defined by the pungh tip along all the press
MCS
Name of the module for the monitoring and control of the functions to use
in safety state of the press brake
MONITORING
Safety function ensuring the intervention of a safety measure if the
capability of a component or an element in executing its function is
reduced
MUTING
Temporary inhibition of the device charged to safety monitoring
OSSD
Output Signal Switching Devices
MUTE POINT
Mute Point: point of the closing stroke where the speed changes from fast
approaching speed (Fast Speed) to safety or work speed, lower than or
equal to 10 mm/sec (Low Speed)
PROGRAMMING
PARAMETERS
MCS parameters which can be changed, through proper procedure, to
configure functions and outputs of MCS
BENDING LAYER
Sliding layer of the bend line during the punch movement
PMI
Bottom Dead Center: lowest point of the moveable table stroke, generally
set by the numeric control to achieve the wished bend
PMS
Top Dead Center: highest point of the moveable table stroke, generally
set by the numeric control to achieve the wished bend
MPMS
Maximum Top Dead Center: highest point of the stroke, achievable by the
moveable table
REDUNDANCY
Use of more than one device or system or parts of them with the aim of
ensuring that, in case of fault of a single component during its function,
another compont is capable to execute that function
RX
Name of the receiver, part of DSP LASER AP, which includes the
sensitive function and the leds
STOP DISTANCE
Distance covered by the moveable table after the interception of the
detection area of DSP LASER AP
DLAM01EN
5
Summary of Contents for DSP LASER AP
Page 2: ......
Page 4: ......
Page 50: ...DSP LASER AP with MCS Figure 34 44 DLAM01EN...