DSP LASER AP with MCS
Foreseen use of the System
DSP LASER AP device has been designed to create on the press brake, as described in
par. 8.1.2, a detection area (volume), by means of the laser beam emitted by the transmitter
and captured by the receiver, to protect the operator who should penetrate it.
Warning
:
DSP LASER AP protects the operator only stopping the movement in
progress of the upper table. Then, it cannot be used in case of material
projection. Then take care in the choice of the material to process, of the
tools and to the possible presence of foreign bodies within the tool
movement area. Transparent objects penetrating the detection area are
not detected.
The device has been designed and manufactured to ensure protection to the operator,
accessing in front of the die area of a press brake, against the dangers due to the
movement of the moveable table during the high speed downstroke. If the operator
intercepts the detection area of DSP LASER AP during the high speed downstroke, the
movement of the moveable table is stopped before the tool installed on it can touch the
operator. The operator, however, must know the risks relevant to the processing on this
type of press brakes.
Warning
:
Pay special attention to the tool shape, which must not exceed the
protection area generated by the laser.
Anyway the device does not replace the necessary training of the personnel and the
information relevant to the residual risks described in chap. 12
Residual risks
.
MCS module has been designed to monitor the parts and the functions which the different
press brake models usually have in common.
Should the monitored parts not work as foreseen and the function assume logics or produce
abnormal values, MCS ensures the STOP of what monitored.
The typical use of the system foresees the mechanical installation of the transmitter and of
the receiver on the upper table and the installation of MCS module inside the electric panel
of the press brake.
In case of machines with moveable upper table, they move together with the moveable
table. Vice versa, in cases of machines with closing movement upwards, the transmitter and
the receiver remain fixed with the upper tool, being understood all other considerations are
the same.
Electric installation must respect what reported in this manual and, in any case, be in
compliance with what foreseen by the current laws regarding the safety installation for
industrial use.
Any use different from those clearly allowed and reported in this use and maintenance
manual of DSP LASER AP and MCS module is, and must be considered, forbidden.
For these uses not allowed and/or not foreseen by NUOVA ELETTRONICA s.n.c. of Pasqui
F. & C., any kind of explicit and implicit warranty decays, as any responsibility for possible
accidents.