DSP LASER AP with MCS
LEDs installed on machine board and controlled by MCS
The LEDs installed on machine board by the Manufacturer must match the requirements
regarding the colour and the position on the machine as required by the current laws.
•
LED Reset Emergency:
ON when the alarm of the Emergency chain has been activated.
OFF when the alarm of the Emergency chain has not been activated or has been
correctly reset.
•
LED Reset Rear Guards:
ON when the alarm has been activated by the open rear guards or by the
photoelectric barrier.
OFF when the alarm of the rear guards has not been activated or has been correctly
reset.
•
LED Sheet Edge request:
Fast Blinking: the Stop Distance Check function is active. It is necessary to execute
the test pressing the downstroke pedal and wait for the machine automatically stops.
Fixed ON: Sheet edge detection function active. You must make DSP LASER AP –
RX detects the edge of the sheet to work placing it on the die, pressing the
downstroke pedal and waiting for the machine stops.
OFF: MCS in working mode.
•
LED Foot Pedal control nr.1:
Fixed ON: Foot Pedal control nr.1 active and system ready to work.
OFF: Foot Pedal control nr.1 not selected, the alarm of the Emergency chain has
been activated or the alarm of open rear guards has been activated (or rear
photoelectric barrier interrupted). In mode 2 Pedals Master-Slave, the pedal pressing
sequence has not been carried out correctly.
Slow Blinking: in mode 2 Pedals, the downstroke pedal of Foot Pedal control nr.2 is
pressed.
Fast Blinking: antipanic alarm activated.
•
LED Foot Pedal control nr.2:
Fixed ON: Foot Pedal control nr.2 active and system ready to work.
OFF: Foot Pedal control nr.2 not selected, the alarm of the Emergency chain has
been activated or the alarm of open rear guards has been activated (or rear
photoelectric barrier interrupted). In mode 2 Pedals Master-Slave, the pedal pressing
sequence has not been carried out correctly.
Slow Blinking: in mode 2 Pedals, the downstroke pedal of Foot Pedal control nr.1 is
pressed.
Fast Blinking: antipanic alarm activated.
•
LED Upper Tool Holder:
Fixed ON: Upper tool holder open.
OFF: Upper tool holder closed.
•
LED Lower Tool Holder:
Fixed ON: Lower tool holder open.
OFF: Lower tool holder closed.
•
Yellow blinker:
Blinking ON: the machine can move in slow speed with the front protection (DSP
LASER AP) inhibited.