DSP LASER AP with MCS
If the object is not removed, the machine can continue the closing movement only in Low
Speed (safety speed).
Instead, if the object is removed from the active detection area, MCS can continue moving
the machine in High Speed.
When the active sensors of the detection area at the greatest distance from the tip of the
upper tool (Area A) arrive near the sheet, these are set in Muting state and the machine can
continue the stroke, as in Figure 60.
Figure 60
The point where the exclusion of the Area takes place depends on the tolerance set in
parameter A4. If the sheet tolerance is set to 1mm, the exclusion will take place before the
central sensor of Area A is completely shaded by the sheet.
If the tolerance has been set to 4mm, the exclusion will take place 4mm before the central
sensor of the Area A is completely shaded by the sheet.
Areas B and C, remaining active, ensure the protection against the intrusion inside the
protection area of Figure 61.
DLAM01EN
77
Summary of Contents for DSP LASER AP
Page 2: ......
Page 4: ......
Page 50: ...DSP LASER AP with MCS Figure 34 44 DLAM01EN...