DSP LASER AP with MCS
Residual
risk
:
In this operating mode, part of the detection area is inhibited. It is
necessary that the operator is informed about the residual possibility of
squashing between the punch and the die or between the punch and the
piece in processing. In order to minimize the dangerous area, the length of
the tools shall be the minimum necessary for the current processing.
Mode 3: Rear area excluded
Backgauges near the dies
Warning
:
This function must be used only when strictly necessary for the type of
work to do. It is then responsibility of the employer to verify the correct
use of the function and forbid its abuse.
In some cases the backgauges could intercept the rear protection area causing the stop of
the press, even if the operator is out of the dangerous area. In order to avoid this situation
and, at the same time, to keep the operator protected, the operating mode 3 can be set.
Figure 66
All the reception areas, except the rear one, are active and the shading of any element
causes the state OFF of the RX outputs. The control device MCS will stop the closing
movement of the machine in high speed (> 10 mm/s).
Persisting the condition of shading of part or whole the active detection area, the release of
the downstroke command and the new pressure allow the machine continue the closing
stroke in low speed (less than or equal to 10 mm/s). Instead, removing the obstacle returns
DLAM01EN
85