DSP LASER AP with MCS
11.2.1. List of parameters and description
Parameter
Possible values
Description
A1
1÷50
Value of Low Speed to monitor, expressed in
mm/s.
Note. When assigning this value, verify which is
the safety speed allowed by the current law in
force in the country where the machine will be
used.
A2
1÷25
Value of the maximum allowed Stop Distance.
After the test of the Stop Distance, in order the
test is successful, the measured distance must
be less than that assigned to this parameter.
The value is expressed in mm.
A3
100, 200, 500, 1000
Resolution of the connected Encoders. The
value is expressed in pulses/mm.
A4
1÷4
Value of the Tolerance for the exclusion of the
laser beam during the approaching to the Sheet
Edge. A greater tolerance will allow using even
slightly corrugated sheets, but the speed
change point of the tolerance value shall be
increased. The value is expressed in mm.
A5
0÷500
Distance to cover in High Speed before the stop
for the calculation of the Stop Distance. The
value is expressed in mm.
A6
100-2000
Maximum time necessary to the press to move
from the moment when MCS commands the
safety outputs to operate a movement. The
value is expressed in ms.
A7
1÷200
Maximum value of the misalignment between
Axes Y1 and Y2. The value is expressed in
mm.
A8
20-1500
Maximum time necessary to Monitors 1 and 2
to switch from the moment when MCS
commands the safety outputs OUTS1 and
OUTS2 from state OFF to state ON.
A9
20-1500
Maximum time necessary to Monitors 3 and 4
to switch from the moment when MCS
commands the safety outputs OUTS3 and
OUTS4 from state OFF to state ON.
B1
OFF/ON1/ON2
Enables/disables the use of the outputs OUTRL
for the command of the Relays for the Auxiliary
Emergency.
OFF: emergency relay outputs disabled.
ON1: emergency relay outputs enabled and
active when the machine is not in emergency.
ON2: emergency relay outputs enabled and
active when the machine is not in emergency
and the side guards are not both open. When
the side guards are opened or closed, the
outputs deactivate for 1 second and re-activate
if the previous conditions are present.