62
ENGLISH
Least group: 0 - 1 - 2 - 3 (
UP/
DOWN to switch).
Least serve: 0 - 1 - 2 - 3 (
UP/
DOWN to switch).
DIRECT LINKS
In "machine ready" state you can go direct to the
settings below instead of surfing the menu.
SETTING THE TEMPERATURE POINT:
+
press ENTER + UP to go
directly to the Setting Point menu (this will be
bars or °C/°F depend on the status view you
were).
press UP or DOWN to move up
and down the working Point.
• Press
to confirm and pass to the
next step.
MONITORING UNIT (°C/°F – BAR)
The display can also show you the pressure or
temperature status of the boiler; to pass from
one to the other, press the
key on the
display.
In the case of pressure, the reading will be
shown in bar, while for temperature, it will be in
degrees Celsius (°C) or Fahrenheit (°F). The
display setting for the temperature can be cho-
sen from the setpoint setting page. In fact, when
choosing the temperature mode, the setpoint will
be shown in degrees Celsius or Fahrenheit
according to the chosen measurement.
7.4
PROGRAMMING
AURELIA V
DOSE PROGRAMMING
To access the programming units, proceed as
follows:
NOTE: the procedure can be carried out with
the machine on.
• To access the dose programming state of
each unit press the first unit’s continuous
delivery
key for 5 seconds.
• The delivery keys will begin to flash on and
off.
• Access into the first unit’s programming
allows you to set the machine’s function
parameters.
COFFEE DOSE PROGRAMMING
To program the relative water doses for one of
the delivery keys, proceed as follows:
• fill the filter-holder with the correct dose of
coffee (the filter-holder can be single or
double depending on the key you wish to
program).
• Insert the filter-holder into the unit.
• The delivery will start; once the desired
amount has been reached, press the con-
tinuous
keys.
• The delivery will stop and the chosen dose
key will turn off (the other keys will continue
to flash).
• Press the continuous
key to exit pro-
gramming or to continue programming other
dose keys..
NOTE: This procedure is usable on all the
machine units except if carried out one
at a time; the other groups can carry on
normally.
HOT WATER PROGRAMMING
• Access the programming according to the
relative procedure.
• Press the hot water selection key
• Hot water delivery will start.
• Establish the desired hot water dose and
press the key again
.
• Press the continuous
key to exit the
programming or to continue programming
other selection keys.
Technician: To enable the pump while hot
water is being dispensed, enter the pro-
gramming mode for the first dispensing
group then press the continual button
for the second group.
ON OFF STAND-BY
(ENERGY SAVING MODE)
This allows to rotate into the three working
modes/statuses.
Press RESET for 3 sec to switch on
off
stand-by the machine status.
• Press one of the delivery buttons (see illus-
tration):
Summary of Contents for Aurelia
Page 1: ...LIBRETTO ISTRUZIONI USER HANDBOOK ...
Page 2: ......
Page 6: ...4 ITALIANO ...
Page 42: ...ENGLISH 40 ...
Page 79: ...NOTE NOTES ...
Page 80: ...NOTE NOTES ...
Page 81: ......