6.  Putting the machine into operation 

 
In order to set the machine into operation several general steps are required. The information on 
the service functions can also be found in the instruction manual 
 
DIGITAL WHEEL BALANCERS 
 

Via the function key 

 you get into the menu for service functions to select the basic 

settings or change them according to the user’s requirements. The various menu functions from 
F1 to F14 can be selected by pressing the +- keys  
 
 
When you are in the function menu, an „Fn“ is shown on the left side of the digital display. The 
chosen function is shown on the right side of the digital display. 
Once a particular function is desired, it can be chosen by pressing the function key again 
 
Perform the following steps in the order stated below 
 
F 5 

Calibration 

 
The calibration weight supplied with the machine must be used 
together with the clamping adapter. Make sure that the threaded hole 
on the adapter is in line with the red indicator marking on the main 
shaft. 
For calibration the calibration weight (1987009WG3) is required 
 

MACHINES with manual clamping of the wheel 

Remove cone and clamp from the main shaft. 
 

MACHINES with QuickSpan

Attach the pressure cup for steel rims to the clamping 
sleeve and activate the QuickSpan

 

 
Press the function key to select the function menu. 
Use +/- keys to select the Function 5. 
Press function key again to activate the function. 
 

Summary of Contents for ATT BM 11

Page 1: ...Page 1 of 15 Quick Installation guide BM Wheel Balancers new generation from Oct 2010 Status 10 December 2013...

Page 2: ...Page 2 of 15...

Page 3: ...Assembling the machine 4 3 Mounting the wheel hood 5 4 Mounting the weight tray and the LE Display 6 5 Mounting the Touch PC 7 6 Putting the machine into operation 8 7 Electrical schematic layout 12 8...

Page 4: ...or BM x5 types including monitor boom Carton with documentation Weight pliers wheel weight removal tool cones quick nut clamping sleeve for QuickSpan models pressure cup for steel wheels distance ring...

Page 5: ...he bag together with the instruction manual View from top View from inside of cabinet The connecting cable of the wheel hood switch has to be routed through the bore holes in the cabinet and the conne...

Page 6: ...net Guide the cables for the LE Display through the hole in the weight tray and mount the weight tray to the cabinet The plugs on the cables and the connectors on the display board are marked with num...

Page 7: ...for the outside arm if present have to be connected is located inside the cabinet Guide the serial cable and the power supply cable through the monitor boom and mount the weight tray to the cabinet C...

Page 8: ...ht side of the digital display Once a particular function is desired it can be chosen by pressing the function key again Perform the following steps in the order stated below F 5 Calibration The calib...

Page 9: ...libration weight Machines with manual QuickSpan clamping of the wheel 2nd Measuring run Run with calibration weight on the left side of the mid centering device Machines with manual QuickSpan clamping...

Page 10: ...the memory even after switching off the power After the run has finished the program automatically changes to normal mode MACHINES with QuickSpan Attach the pressure cup for steel rims to the clamping...

Page 11: ...15 WHEEL BALANCERS WITH TOUCH PC The settings described above for the digital wheel balancers are easily done by touch operation Calibration and zero run Button for machine calibration Button gauge c...

Page 12: ...Page 12 of 15 7 Electrical schematic layout Basic Board...

Page 13: ...Page 13 of 15 Motor control board F2 5V 12V F3 12V F4 12V...

Page 14: ...Page 14 of 15 8 Dimensions...

Page 15: ...Page 15 of 15 9 Technical data...

Reviews: