There are 3 measuring runs performed during the calibration procedure, the wheel guard (if
present) can be left open:
1
st
Measuring run
Run without calibration weight
Machines with manual
QuickSpan
clamping of the wheel
2
nd
Measuring run
Run with calibration weight on the left side of the mid centering device
Machines with manual
QuickSpan
clamping of the wheel
3
rd
Measuring run
Run with calibration weight on the right side of the mid centering device
Machines with manual
QuickSpan
clamping of the wheel