36
OPI-POWER LIFT HF 3S 8000-V1.0-EN
3. Set to the desired height (from 100 mm to 900
mm in 100 mm steps) depending on the ceiling
height.
4. Fasten the extension using the long screws after
the tensioning plate (A) has been placed.
A
5. Fasten the cover.
6. Remove existing hydraulic lines. Do not remove
colour markings.
7. Loosen and turn the T-piece and bracket visible
in the figure.
Exchange the supplied hydraulic hoses
1. Place yellow and white on the top of the operat-
ing column.
2. Attach red directly to the unit.
3. Connect blue to K1 of the operating column.
4. Cut the cover panel to length and mount.