background image

Automatic Thermostat-Controlled – Fan forced.
1250 WATTS - 120vAC, 60Hz

DIMENSIONS:

HOUSING - 8

1

2

" x 12

1

2

" x 4"

GRILLE - 10

1

8

" x 14

1

8

"

1.

Refer to Figure 1. 

Remove heating element assembly

from housing by unscrewing from brackets on either
side of element. Keep screws.
Mount housing at least 6" above finished floor (to
provide clearance for grille).

2.

Refer to Figure 2. 

Insert provided mounting brackets

in housing. Extend brackets so that unit will fit between
wall studs. Fasten housing to stud and brackets to
opposite stud.

NOTE: To give clearance for switch operation,
make certain housing flange is flush to finished
wall.

3. Nail or screw housing to wall stud through holes in side

of housing. If necessary, make cutout - 8

1

2

" x 2

1

2

" -

along side of wall stud.

IMPORTANT: Do not mount over tub or in shower
stall enclosure.

4. Run 120vAC house wiring with ground to heater

location and secure to junction box with box connector
(not provided).

5. When finished wall is up, replace heating element

assembly in housing; fasten screws through brackets
on either side of element.

6. Insert heater wires into junction box. Connect house

wiring to heater wiring as follows: BLACK to BLACK;
WHITE to WHITE; GROUND to GREEN GROUND
SCREW in box.

CAUTION: Be sure all wiring conforms to local codes
and unit is properly grounded.

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Wall Heater

MODEL: 9376N

FIGURE 1

FIGURE 2

HEATING
ELEMENT
ASSEMBLY

SCREWS

BRACKET

BRACKET

(Please see other side.)

Reviews: