background image

®

Page

MODELS  AVD40N • AVD40KN • AVD40WN 

AVD45N • AVD45KN • AVD45WN • AVD50N

BUILT-IN IRONING CENTER

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION 

(Fig. 1)

1.  DETERMINE WALL OPENING.

The NuTone Ironing Centers are designed to fit between standard 16” on-center 

wall studs. A 49-1/4 ” x 14-1/8 ”x 3-7/8” deep opening is required. 24” on-center 

studs will require framing to proper opening size.

2.  DETERMINE DISTANCE ABOVE THE FLOOR.

Use the following chart to determine the recommended wall opening above 

the floor:

  Wall Opening 

Working Height

 

Above the Floor 

 

AVD40/45 Series 

AVD50 Series

  24”  

 

30”  

29”-30½”-32½”

  28”  

 

34”  

33”-34½”-36½”

  30” 

  

36”  

35”-36½”-38½”

  32”  

 

38”  

37”-38½”-40½”

3.  ATTACH CLEATS.

Fasten  2x4  cleats  to  wall  studs  to  provide  a  level  surface  on  which  to  rest 

cabinet.

4.  MOUNT CABINET.

Lift  cabinet  into  place  and  attach  it  to  studs  using  the  six  supplied  screws. 

Mounting holes positions are indicated by the arrows. On AVD45 and AVD50 

Series models, remove the wireway cover to access mounting hole. Be sure to 

allow for wall covering thickness behind cabinet face frame. Plumb and shim 

cabinet to fit.

5.  CONNECT WIRING (Fig. 2) 

(AVD45 & AVD50 Series only)

Remove wireway cover. Bring house wiring into cabinet access hole and attach 

wiring to cabinet with an approved wire strain relief. Connect black to black, 

white to white and green/bare wire from house wiring to ground fixing terminal 

at the top end of the cabinet. Replace cover.

WARNING

AVD45 and AVD50 Series Only

ALL  ELECTRICAL  WORK  MUST  BE  DONE  IN  ACCORDANCE  WITH 

LOCAL  AND/OR  NATIONAL  ELECTRICAL  CODES  AS  APPLICABLE. 

FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. IF YOU ARE 

UNFAMILIAR WITH METHODS OF IN STALLING ELECTRICAL WIRING, 

SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

The ironing center should be installed on a SEPARATE 15 amp circuit to 

prevent circuit overload.

TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING 

WIRING OR SERVICING THIS PRODUCT.

1.  Do not place EXCESSIVE WEIGHT (weight should not exceed 30 pounds) 

on the ironing board when opened as it is designed to accept normal ironing 

use only.

2.  Allow iron to cool down before storing in the cabinet.

3.  Empty water reservoir and turn off steam action prior to storing iron.

4.  Turn power off when not in use.

5.  Do not remove the board retainer.

6.  The appliance is supplied with approved components and wires which must 

not be changed. If any components or wires of this equipment is damaged, it 

must only be replaced by the manufacturer, service agent or similarly quali-

fied person in order to avoid hazard.

7.  This unit may be installed as a surface mount. If installed in this manner, you 

MUST USE the Surface Mount Collar Assembly (AVDSMN). See instructions 

included with Assembly, for mounting by this method.

CAUTION:  DO  NOT  ALLOW  WIRE  TO  EX-

TEND OUTSIDE OF WIRING BOX. EXPOSED 

WIRES CAN BECOME PINCHED AND ELEC-

TRICAL SHOCK HAZARD MAY RESULT.

Fig. 1

Fig. 2

Summary of Contents for AVD50N

Page 1: ...g to ground fixing terminal at the top end of the cabinet Replace cover WARNING AVD45 and AVD50 Series Only ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND OR NATIONAL ELECTRICAL CODES A...

Page 2: ...e cabinet Attach the hinge to cabinet and door using the screws supplied Use the decorative plugs supplied to cover the remaining pre punched holes Flat Head 6 x 1 2 Door to Hinge Hinge to Cabinet Pan...

Page 3: ...noir le blanc avec le blanc et le c ble vert du c blage de la maison l extremit terre en haut du meuble Remettez le couvercle ATTENTION Uniquement pour le s rie AVD45 et AVD50 Toute l installation l...

Page 4: ...et en bas du meuble Fixer les charni res au meuble et la porte l aide des vis fournies Utiliser les embouts d coratifs fournis pour couvrir les trous non utilis s T te Plate 6 x 1 2 Porte Charni re e...

Page 5: ...n el extremo a la terminal instalada en la cubierta superior del gabinete Reinstale la cubierta de cables del gabinete ADVERTENCIA nicamente series AVD45 y AVD50 LA INSTALACI N EL CTRICA DEBE SER HECH...

Page 6: ...en el gabinete y f jelas a la puerta usando los tornillos provistos Use los tapones provistos para cubrir los hoyos no usados en el gabinete Cabeza Plana 6 x 1 2 Puerta Bisagra y Bisagra Gabinete Cabe...

Page 7: ...AVD50N AVD45KN AVD45WN AVD45N AVD40KN AVD40WN AVD40N DESCRIPTION DESCRIPCI N 1 99525227 99525228 99525227 99525228 Door Porte Puerta 5 99523913 99523913 99523913 99523913 Signal light assembly Assemb...

Page 8: ...7 99150604 99150604 99150604 99150604 99150604 99150604 99150604 Screw 6 20 AB X 375 PAN PH HC Vis 6 20 AB X 375 PAN PH HC Tornillo 6 20 AB X 375 PAN PH HC 39 99525229 99525229 99525229 99525229 99525...

Reviews: