background image

INST
ALLA
TION MANUAL

INST
ALLA

TION

13

FRAMED CABINET

7/64”

X

Y

Z

Refer to the marking on brackets to determine the correct installation side and orientation.



Mate the corresponding bracket to the cabinet side frame, while placing rear end 

 

of bracket against the wall. Use a pencil to mark 3 holes (there are 6 holes but only 

 

3 are necessary).



Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked.



Assemble the bracket to the side frame using a Phillips screwdriver and 3 provided 

 

no. 8 x 5/8” wood screws. Repeat for the other side frame.

7 ]  

Install the proper installation brackets according to the type of cabinet (framed or frameless). 
See below.

4 ]

  Drill a 1/8” dia. pilot hole for house wiring, at 

A

 location on template. 

5 ]  

Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access 
holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the 
template.

6 ]  

 Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for 
rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall 
(horizontal exhaust). Drill the house wiring hole by using a 1½” hole saw centered with the 
pilot hole previously made in 4.

Summary of Contents for BQSEN1 Series

Page 1: ...WWW BROAN CA Serial number 99045657 006D RANGE HOOD Series BQSEN1 and NQSEN1 INSTALLATION USE AND CARE MANUAL WWW NUTONE CA ...

Page 2: ...nstallation 7 20 Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 8 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installation 12 14 Install the Hood EZ1 Bracket 15 16 Standard Installation 17 Install the Hood Standard Installation 18 Connect the Wiring 19 Install the Filters 19 Wiring Diagram 20 Service Parts 21 Warra...

Page 3: ...luding fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning En...

Page 4: ...and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and nois...

Page 5: ...r Operate the hood as follows BLOWER SWITCH I Turns blower on to LOW speed Turns blower OFF II Turns blower on to HIGH speed LIGHT SWITCH I Turns light ON Turns light OFF The LED modules included with this hood are the latest in LED cooktop illumination technology specially designed to operate in the elevated temperatures of cooking offering bright lighting and lasting up to 25 times as long as a ...

Page 6: ...BLADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized...

Page 7: ...ly SOFFIT 18 MIN 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 round or horizontally 3 x 10 only 2 Decide where the ductwork will run between t...

Page 8: ...CONDUIT RECTANGULAIRE CONDUIT ROND DE 7 PO OU 3 pulg x 10 pulg 3 pulg x 14 pulg CONDUCTO RECTANGULAR CONDUCTO REDONDO DE 7 PULG O Appuyer ce bord au mur arrière Utiliser ce gabarit pour marquer vos repères ne pas tenter de découper le trou pour le conduit à travers le gabarit NOTE Les découpes incluent le jeu nécessaire à l installation elles ne doivent pas être du format exact des conduits Use es...

Page 9: ...ilter out 3 Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper assembly from inside the hood and keep the screws for further use 4 Remove the wiring cover shaded part on illustration below by sliding it out from the hood and set it aside B C DAMPER ASSEMBLY SC...

Page 10: ...move Electrical Power Cable Knockout from top vertical wiring or back horizontal wiring of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the recirculation cover plate shaded part in illustration below to the hood Discard this plate with its screws ELECTRICAL POWER CABLE KNOCKOUT SCREWS ...

Page 11: ...2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B 9 Attach 3 x 10 Damper Assembly on top OR back of hood if using 3 x 10 duct shaded part in FIGURE 2 A b...

Page 12: ...CAL EXHAUST A S A A V RTICAL EX 3 x 10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the exact size of ducting 3 po x 10 po 3 po x 14 po CONDUIT RECTANGULAIRE CONDUIT ROND DE 7 PO OU 3 pulg x 10 pulg 3 pulg x 14 pulg CONDUCTO RECTANGULAR CONDUCTO REDONDO...

Page 13: ...ews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A location on template 5 Use a sharp pencil or 1 8 drill bit to mark the locations for the appropriate duct access holes 16 locations for 7 round duct or 4 corner locations for rectangular duct Remove the temp...

Page 14: ...l Draw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to mark 3 holes Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws Repeat...

Page 15: ... holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 10 4 Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT HOLES C and D Attach power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood run the house power ca...

Page 16: ...arts bag Insert 2 screws per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws included in parts bag Insert 2 screws per side in the slots as shown in insets on illustration below FRAMED CABINET FRAMELESS CABINET WOOD SCREWS METAL SCREWS ...

Page 17: ...ncluded VERTICAL DUCT ACCESS HOLE 1015 16 5 5 CENTER LINE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1Ǫ 1 7 16 12Ǭ 47 16 CABINET BOTTOM 12Ǭ 3 X 10 VERTICAL DUCTING CABINET BOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN WALL 3Ǭ CENTER LINE WOOD SHIMS RECESSED BOTTOM CAB...

Page 18: ...ood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood While holding the hood tighten screws securely Attach power cable to the hood using the strain relief OTE N Two installers are recommended because of the weight of this hood DUCTED INSTALLATION ONLY 3 Connect ductwork to hood and use metal foil duct tape to make joints secure and air tight Ma...

Page 19: ...tabs on inner top of hood are engaged in their corresponding slots in wiring cover Also take care not to pinch wires while reinstalling wiring cover SCREW 2 Reinstall wiring cover and attach it to the hood using its retaining screw TABS ON INNER TOP OF HOOD ENGAGED IN WIRING COVER SLOTS MOTOR GROUND WIRE HOUSE POWER CABLE GROUND SCREW Install the Filters Ducted Installation Only Re install grease ...

Page 20: ... Y W BK O R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch BL W W BK BK COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE R BK R W LED LED LED driver 1 2 3 4 5 6 2 2 1 1 ...

Page 21: ... BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCL 4 CLIPS 1 1 S97020470 EASY INSTALL KIT INCLUDING HARDWARE 1 1 ITEM NOT SHOWN REPLACEMENT PARTS AND REPAIRS In order to ensure your unit remains in good working...

Page 22: ...ent parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage in transit The Company reserves ...

Reviews: