- 6 -
INSTALL MOUNTING
BRACKETS
1. Construct wood wall framing that is flush
with interior surface of wall studs.Make
sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting brackets to be secured to
the framing within the dimensions
shown.
2. After wall surface is finished, secure mount-
ing brackets to framing using dimensions
shown.
FRAMING BEHIND DRYWALL
29-7/8” to 35-7/8” above
cooktop
29-7/8" = bottom of hood 24"above cooktop
35-7/8"= bottom of hood 30" above cooktop
36” MODEL
FRAMING BEHIND DRYWALL
29-7/8” to 35-7/8” above
cooktop
29-7/8" = bottom of hood 24"above cooktop
35-7/8"= bottom of hood 30" above cooktop
11-13/16”
48” MODEL
19-11/16”
IN-LINE BLOWER