Page 5
ALLURE™ WS15 SERIES
RANGE HOOD
INSTALL HOOD
KEYHOLE
(4)
MOUNTING
SCREW
(4)
1
Hang hood from (4)
Mounting Screws (from parts bag).
Slide hood towards wall until mounting screws are engaged
in narrow end of (4)
Keyholes. Tighten mounting screws
securely.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)
5
Replace filters and make sure fan blade turns freely. Turn on
power at service panel, and test for proper operation.
2
Connect ductwork to hood. Use
Duct Tape to make joints
secure and air tight.
DUCT
TAPE
CAUTION
DO NOT PUSH ON FAN BLADE. Pushing on the
blade may cause it to interfere with other hood parts.
3
Install (2) PAR20, 50 W Maximum
Halogen Bulbs or (2)
R16, 40 W Maximum
Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION:
Bulbs may be hot! Refer to bulb packaging
for further information.
OPERATION
Fan and Lights: 3 push button switches for each. Push any but-
ton to select one of 3 fan speeds or one of 3 light levels. Push the
same button to turn fan or light off. Press another button to change
fan speed or light level. A light above each fan button indicates the
fan speed.
Heat Sentry: Your range hood is equipped with the Heat Sentry
feature, which monitors temperature. The Heat Sentry will automati-
cally turn the fan on at its highest speed when the temperature is
above normal.
1) If a fan setting is selected when the Heat Sentry in on, the light
above the fan button will flash on and off.
2) If the fan setting is off when the Heat Sentry is on, the light above
fan button 3 will flash on and off rapidly.
After the temperature has lowered to normal, the fan will change to
the setting prior to the Heat Sentry turning on.
Fuse: The hood control contains a fuse to protect it from power
surges. If the fuse has opened (blown), the green fan-level indicators
will operate properly when the fan buttons/switches are pressed - but
the fan and lights will not turn on.
The fuse is a 5 x 20 mm, 10 Amp, Fast-Acting, 125V (min.). Common
manufacturer and part numbers are: Littlefuse, 217010; Bussmann,
GMA10A; Wickmann, 1942100. Radio Shack, Digikey (1-800-344-
4539), and most electronic supply stores have them in stock.
To replace the fuse:
1. Disconnect power at service entrance.
2. Remove filters, bottom panel, light wire harness, and air chute.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics need to be done.
4. Install new fuse.
5. Re-assemble air chute, light wire harness, bottom panel, and
filters.
6. Turn on power and check hood/control operation.
NOTE:
This hood utilizes an offset blower design to achieve greater
performance and lower sound levels. As a result, you may notice
that cooking impurities are more attracted to one side or appear
to be pulled-in faster than they appear on the opposite side. This
is completely normal. The hood has been designed and tested to
provide good capture of cooking impurities and odors under all
normal cooking conditions regardless of the cooking location on the
cooktop. Please note that cooking on the rear burners will always
result in the best capture results, regardless of the hood design.
4
Remove plastic protective film from outer frame of filters.