background image

Page 5

ALLURE™   WS15 SERIES

RANGE  HOOD  

INSTALL HOOD

KEYHOLE 

(4)

MOUNTING

SCREW

(4)

Hang hood from (4) 

Mounting Screws (from parts bag). 

Slide hood towards wall until mounting screws are engaged 

in narrow end of (4) 

 Keyholes. Tighten mounting screws 

securely.

PAR20,

50W MAX.

HALOGEN

BULB (2)

- or -

R16,

40W MAX.

INCANDESCENT 

BULB (2)

Replace filters and make sure fan blade turns freely. Turn on 

power at service panel, and test for proper operation.

Connect ductwork to hood. Use 

Duct Tape to make joints 

secure and air tight.

DUCT

TAPE

CAUTION 

DO NOT PUSH ON FAN BLADE. Pushing on the  

 

blade may cause it to interfere with other hood parts.

Install (2) PAR20, 50 W Maximum 

Halogen Bulbs  or (2) 

R16, 40 W Maximum 

Incandescent Bulbs. Purchase bulbs 

separately.

!

CAUTION: 

Bulbs may be hot! Refer to bulb packaging 

for further information.

OPERATION

Fan and Lights: 3 push button switches for each. Push any but-

ton to select one of 3 fan speeds or one of 3 light levels. Push the 

same button to turn fan or light off. Press another button to change 

fan speed or light level. A light above each fan button indicates the 

fan speed.

Heat Sentry: Your range hood is equipped with the Heat Sentry 

feature, which monitors temperature. The Heat Sentry will automati-

cally turn the fan on at its highest speed when the temperature is 

above normal.
1) If a fan setting is selected when the Heat Sentry in on, the light 

above the fan button will flash on and off.
2) If the fan setting is off when the Heat Sentry is on, the light above 

fan button 3 will flash on and off rapidly.
After the temperature has lowered to normal, the fan will change to 

the setting prior to the Heat Sentry turning on.

Fuse: The hood control contains a fuse to protect it from power 

surges. If the fuse has opened (blown), the green fan-level indicators 

will operate properly when the fan buttons/switches are pressed - but 

the fan and lights will not turn on.
The fuse is a 5 x 20 mm, 10 Amp, Fast-Acting, 125V (min.). Common 

manufacturer and  part numbers are: Littlefuse, 217010; Bussmann, 

GMA10A; Wickmann, 1942100. Radio Shack, Digikey (1-800-344-

4539), and most electronic supply stores have them in stock.
To replace the fuse:

1.  Disconnect power at service entrance.

2.  Remove filters, bottom panel, light wire harness, and air chute.

3.  Remove and inspect fuse. If it is not open (blown), additional 

diagnostics need to be done.

4.  Install new fuse.

5.  Re-assemble air chute, light wire harness, bottom panel, and 

filters.

6.  Turn on power and check hood/control operation.

NOTE:

This hood utilizes an offset blower design to achieve greater 

performance and lower sound levels. As a result, you may notice 

that cooking impurities are more attracted to one side or appear 

to be pulled-in faster than they appear on the opposite side. This 

is completely normal. The hood has been designed and tested to 

provide good capture of cooking impurities and odors under all 

normal cooking conditions regardless of the cooking location on the 

cooktop. Please note that cooking on the rear burners will always 

result in the best capture results, regardless of the hood design.

Remove plastic protective film from outer frame of filters.

Summary of Contents for WS15 SERIES

Page 1: ...t TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or t...

Page 2: ...ILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round horizontally 3 x 10 only or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted install...

Page 3: ...th one 1 screw NOTE Be care ful not to discon nect any wires 9 Rotate baffle Re insert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An audible click will be heard when fully installed This will close off the air flow through the non ducted slots on top of hood 10 Re install air chute re connect wire harness and replace light panel NOTE Be careful not t...

Page 4: ...NOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge 13 7 Round Ducted Discharge Only Re install 7 Round Duct Plate removed in Step 1 under PREPARE THE HOOD section Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood 12 3 x 10 Ducted Discharge Only Attach Damper Duct Con...

Page 5: ...t Sentry is on the light above fan button 3 will flash on and off rapidly After the temperature has lowered to normal the fan will change to the setting prior to the Heat Sentry turning on Fuse The hood control contains a fuse to protect it from power surges If the fuse has opened blown the green fan level indicators will operate properly when the fan buttons switches are pressed but the fan and l...

Page 6: ...0508 7 Round Duct Plate includes hardware 2 R740013 Damper Duct Connector includes hardware 3 R602017 Screw 8 18 x Hex 2 in package 4 99091152 Nameplate 5 R602534 Screw 8 18 x 3 8 2 in package 6 R602533 Ground Screw 2 req 7 98010725 Wiring Cover includes hardware 8 Rivet Pop 125 dia 9 R169016 Filter Spring Kit 10 R169002 Motor Mounting Screw 3 each part 11 R99080535 Motor includes Motor Mounting K...

Page 7: ... LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal después apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUEYAVISEA LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podrá quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosión de vapor violenta 4 Utilice un exti...

Page 8: ...ana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal sólo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin conductos En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde va a instalar la campana y la tapa de techo o la tapa de pared Para obtener los mejores resultados utilice el número mínimo de transicione...

Page 9: ...r ningún cable 8 Quite el deflec tor del conducto para aire 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera según lo dem ostrado que las aletas entren totalmente en las ranuras del conducto para aire Un tecleo audible será oído cuando está insta lado completamente Esto se cerrará del aire atraviesa las ranuras sin conduc tos encima de la campana 10 Reinstale ...

Page 10: ...te en el caso de descargas con conductos redondos de 17 8 cm 7 12 Sólo para descargas con conductos de 8 3 cm x 25 4 cm 3 x 10 Coloque el conectador del regulador de tiro conducto sobre la abertura del agujero ciego Asegúrese de que el pivote del regulador de tiro quede lo más cerca posible del borde superior posterior de la campana Quite la cinta de la aleta del regulador de tiro CONECTOR DEL REG...

Page 11: ... que se encuentra sobre el pulsador del ventilador destellará 2 Si el ajuste del ventilador está apagado cuando Heat Sentry está funcionando la luz que se encuentra sobre el pulsador 3 del ventilador destellará rápidamente Cuando la temperatura disminuye hasta el valor normal el ventilador regresará al ajuste que tenía antes de que la característica Heat Sentry se encendiera Fusible El control par...

Page 12: ... una garantía implícita por lo que la limitación antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DEBROAN NUTONE DEBERASERELUNICOYEXCLUSIVORECURSOLEGALDELCOMPRADOR BAJOESTAGARANTIA BROAN NUTONENOSERARESPONSABLEPORDAÑOSINCIDENTALES CONSIGUIENTES O POR DAÑOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPEÑO DEL PRODUCTO Algunos es...

Reviews: