Electrical Connection
WARNING
Connection must only be carried out by suitably trained, qualified and skilled
engineers, in accordance with all regional and local electrical codes.
Flexeserve Hub® products are designed to be installed with dedicated power cords.
POWER SUPPLY
COUNTRY/REGION
10 AMP 1 PH
Australia
13 AMP 1 PH
UK
15 AMP 1 PH
Australia
16 AMP 1 PH
UK / Sweden
The equipment must be connected to a branch circuit protected grounded supply in accordance with
local electrical codes.
Each unit must have its own dedicated power supply.
NOTE
For electrical ratings of the unit, refer to the electrical rating sticker located inside the front top
panel of Flexeserve Hub®. An example is shown below.
It is highly recommended to provide the equipment with an accessible means of isolation external to the
equipment, i.e., a wall isolator switch.
Electrical Ratings
The appliances are electrically rated for a 230V, 50Hz electrical supply.
TOTAL POWER
MODEL
600
1400 W
1000
2700 W
Electrical rating